본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Prolactin Monomeric Polyethylene Glycol Measurement Method and Study of Reference Value Verification

이용수  0

영문명
발행기관
대한핵의학기술학회
저자명
Dong Hyuk Ha Hwa-Jin Ryu Hyun-Su Cho Sun-Young Shin
간행물 정보
『핵의학기술』Vol.27 No.2, 133~136쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2023.11.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Purpose: Prolactin in the blood is separated into three types, and over 90% of prolactin presents as a double monomer (23 KDa). Rarely, it can exist in the size of big prolactin (150 KDa), which is called macroprolactin and is known as an autoantibody complex. When macroprolactin accounts for more than 60% of prolactin in the blood, it is called macroprolactinemia. The presence of such macroprolactin was first reported in a patient with hyperprolactinemia but without typical symptoms. Macroprolactinemia is emerging as an important cause of idiopathic hyperprolactinemia. The polyethylene glycol (PEG) precipitation method using the property of precipitating large-molecular-weight proteins is simple and recently has been widely used as a screening test. The results are in good agreement with the results of gel chromatography. The purpose of this study was to confirm the measurement method and reference value verification of monomeric prolactin in blood prolactin using the PEG precipitation method. Materials and Methods: For 40 examinees who visited the Gangnam Center of Seoul National University Hospital in 2021, the prolactin level was verified using radioimmunoassay (RIA). For macroprolactinemia PEG precipitation method, 25% PEG (molecular weight 6000kDa) solution and serum were mixed in equal amounts in a test tube, then left at room temperature for 20 minutes and centrifuged at 4℃ for 30 minutes (1500g). The prolactin level was measured in the supernatant. Results : After confirming that more than 90% of the 40 tested samples within the reference range <25 ng/mL, the same value as the reference value for prolactin was applied. Since the concentration of monomeric prolactin in serum from which macroprolactin has been removed from blood is diluted 1:1 with PEG, our laboratory is currently reporting the result by multiplying the result by a dilution factor of 2. Conclusion: Radioimmunoassay using PEG precipitation method using the property of precipitating large molecular weight proteins is simple and effective for quantitative measurement of monomeric prolactin in blood prolactin.

영문 초록

목차

서론 및 목적
대상 및 방법
결과
고찰 및 결론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Dong Hyuk Ha,Hwa-Jin Ryu,Hyun-Su Cho,Sun-Young Shin. (2023).Prolactin Monomeric Polyethylene Glycol Measurement Method and Study of Reference Value Verification. 핵의학기술, 27 (2), 133-136

MLA

Dong Hyuk Ha,Hwa-Jin Ryu,Hyun-Su Cho,Sun-Young Shin. "Prolactin Monomeric Polyethylene Glycol Measurement Method and Study of Reference Value Verification." 핵의학기술, 27.2(2023): 133-136

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제