CT Guided Interventional Sturdy에서 Conventional Scan Mode 적용에 따른 선량 감소에 관한 연구
이용수 19
- 영문명
- The Sturdy for Reduction of Radiation Dose According to Conventional Scan Mode in CT Guided lnterventional Sturdy
- 발행기관
- 대한CT영상기술학회
- 저자명
- 김지혜(Ji Hye Kim) 김문찬(Moon Chan Kim) 남윤철(Yoon Cheul Nam)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제1호, 87~94쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2010.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose
Recently CT guided interventional sturdy applied the helical scan mode which occurred overscanning dose. If you apply conventional scan mode, overscanning dose can be reduced.
This sturdy intend to evaluate dose reduction and image quality from applying the protocol in conventional scan mode that decrease overscanning dose.
Materials and methods
All exams were proceeded on Aquilion 64 of Toshiba and used for ACR and CATPHAN phantom. the average number of pre. San was 1.0±0, scan range was an average of 9.2±2.6 cm in CT guided bone biopsy. the average number of pre. scan was 3.0±1.1, scan range lesion average of 11.1±3.3 cm in CT guided kidney RFA. we scanned repeatedly lesion area inserting the needle into the organ except for pre. scan. 7.2+3.2 times in CT guided bone biopsy, 14.0±5.1 times in CT guided kidney RFA. The conditions of helical scan mode protocol were as followed: 120 kVp, 70 mA, 0.6 sec, 2 mm slice thickness, 8 mm beam collimation, 0.938 pitch, and effective mAs was 45 mAs. to apply same CTDIvol with helical scan mode, the conditions of conventional scan mode were set on 120 kVp, 80 mA, 0.6 sec, 2 mm slice thickness, 8 mm beam collimation.
We estimated the effect of dose reduction from effective dose derived from total DLP of conventional scan mode and thar of helical scan mode. ACR and CATVHAN phantom were used for evaluation of image quality.
Results
The estimate of dose showed total DPL 174.2±51.8 mGyㆍcm, effective dose 3.3±0.9 mSv in conventional scan mode, compared with total DPL 256.6±82.3 mGyㆍcm, effective dose 4.9±1.6 mSv in helical scan mode, which is reduced in 32.1±3.9% in CT guided bone biopsy.
In CT guided kidney RFA, total DPL 465.3±139.7 mGyㆍcm, effective dose 7.0±2.0 mSv in conventional scan mode, compared with total DPL 647.5±200.6 mGyㆍcm, effective dose 9.7±3.0 mSv in helical scan mod, which is reduced in 29.1±6.8%. The result of noise is 15.4 HU in helical scan mode and 21.9 HU in conventional scan mode which is 6.5 HU higher d1an helical scan mode but almost did nor affect the image quality.
Conclusion
Accordingly, in conventional scan mode the ration of dose reduction was approximately 29.1~32.1% clue to decreased overscanning dose and the risk of stochastic effects and deterministic effects was not found in CT guided interventional sturdy. Therefore, we should sturdy more minimize dose for the patient while maintaining image quality through using optimal protocol.
목차
Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
해당간행물 수록 논문
- CT 검사에서 Gantry Aperture의 Isocenter와 피사체 중심의 불 일치 시 선량과 화질의 평가
- CT Guided Interventional Sturdy에서 Conventional Scan Mode 적용에 따른 선량 감소에 관한 연구
- CT실의 환경오염평가와 환경소독에 관한 연구
- Multi-detector Computed Tomography를 이용한 Neck 검사에서 Automatic Exposure Control을 이용한 선량의 최적화
- 폐 소결절 환자를 대상으로 한 CT-guided Wire Marking Procedure에 대한 유용성 평가
- Volume Rendering CT Image의 TACE Reference Data로서의 유용성
- Lumbar Spine Disease 환자의 2D Sagittal Reformation 시 Reformation Angle에 따른 Intervertebral Foramina Image에 대한 고찰
- Adaptive Statistical Iterative Reconstruction 기법의 적용에 따른 Computed Tomography 영상의 화질과 선량 연구
- ECG-gated Cardiac MDCT 검사에서 심장기능 평가를 위한 최적의 수축기말과 확장기말 Phase(%)에 관한 연구
- Multi-detector Computed Tomography에서 환자의 자세 변화에 따른 Esophageal Cancer 진단의 유용성
- Dual Source CT에서 High-pitch Cardiac Scan Mode를 이용한 관상동맥 검사의 유용성
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선사 맞춤형 조영제 정맥주사 교육과정 개발
의약학 > 방사선과학분야 NEW
- 재구성 알고리즘과 Butterworth 필터 차단 주파수가 핵의학 영상 화질에 미치는 영향: Prominence Processor 기반 시뮬레이션 연구
- 합성곱 블록 주의 모듈과 U-Net을 활용한 CT 영상 노이즈 제거 기법
- 요오드 조영제 자동 주입 시 외부 가온기 사용이 온도 변화에 미치는 영향
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!