Adaptive Statistical Iterative Reconstruction 기법의 적용에 따른 Computed Tomography 영상의 화질과 선량 연구

이용수  13

영문명
A Study on Image Quality and Dose of CT Image Using Adaptive Statistical Iterative Reconstruction Algorithm
발행기관
대한CT영상기술학회
저자명
박건진(Kun Jin Park) 방성호(Sung Ho Bang) 김문찬(Moon Chan Kim) 한동균(Dong Kyoon Han)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제1호, 95~104쪽, 전체 10쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Recently many studies had been applied to minimize radiation exposure while also obtaining suitable image quality for diagnosis. This study was focused on the evaluation of image quality and dose of CT image which were applied with adaptive statistical iterative reconstruction(ASIR) to examine the usefulness of image diagnosis. Materials and methods CT scans were performed with a 64-slice MIDCT scanner(GE LightSpeed VCT XTe, waukesha, Wisconsin, USA). CTDI measurement was used for comparing doses while the ACR Phantom was used for image quality comparison. The ASIR was used for image reconstruction which create a noise map based on the filtered backprojection(FBP) and organized a statistical model and blends it with appropriately original FBP image. For image quality comparison in phantom study, CTDIVOL 14.76 mGy for non-ASIR was applied and evaluations were clone by analyzing items such as noise level, olv-contrast and high-contrast resolution. In patient study, test were clone by CTDIVOL 9.45 mGy (standard chest CT dose) and 0.90 mGy, 0.45 mGy, and 0.36 mGy(low dose CT) were delivered with standard and bone kernel. Results In phantom study showed that the upward values of spatial resolution were generally similar among kernels and low-resolution kernels showed excellence of contrast to noise(CNR) above 1.0 compared to high-resolution kernels in ASIR 50 and showed improved CNR even though decreased of dose 40% above. With same Parameters noise level(NL) showed 2% in FBP image, 1.5% in ASIR 30% above, and 1% or less in ASIR 100%. Differentiating by the naked eye was difficult, but the differences between each kernel of ASIR were recognized by measuring resolution and noise by quantitative analysis. The effective dose of the low-dose chest examination held as a patient study was only 0.3 mSv or less. It showed reduction of 90% compared to the standard dose, and similar image quality was maintained by applying ASIR 30~60%. However, high-resolution kernels With high ASIR showed a severe level of noise including streak artifacts. Conclusion CT image reorganization using ASIR is considered to be a useful dose reducing method while maintaining the image quality, when comparing with the existing filtered back-projection (FBP) reorganized images.

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박건진(Kun Jin Park),방성호(Sung Ho Bang),김문찬(Moon Chan Kim),한동균(Dong Kyoon Han). (2010).Adaptive Statistical Iterative Reconstruction 기법의 적용에 따른 Computed Tomography 영상의 화질과 선량 연구. 대한CT영상기술학회지, 12 (1), 95-104

MLA

박건진(Kun Jin Park),방성호(Sung Ho Bang),김문찬(Moon Chan Kim),한동균(Dong Kyoon Han). "Adaptive Statistical Iterative Reconstruction 기법의 적용에 따른 Computed Tomography 영상의 화질과 선량 연구." 대한CT영상기술학회지, 12.1(2010): 95-104

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제