학술논문
Adaptive Statistical Iterative Reconstruction 기법의 적용에 따른 Computed Tomography 영상의 화질과 선량 연구
이용수 13
- 영문명
- A Study on Image Quality and Dose of CT Image Using Adaptive Statistical Iterative Reconstruction Algorithm
- 발행기관
- 대한CT영상기술학회
- 저자명
- 박건진(Kun Jin Park) 방성호(Sung Ho Bang) 김문찬(Moon Chan Kim) 한동균(Dong Kyoon Han)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제1호, 95~104쪽, 전체 10쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2010.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose
Recently many studies had been applied to minimize radiation exposure while also obtaining suitable image quality for diagnosis. This study was focused on the evaluation of image quality and dose of CT image which were applied with adaptive statistical iterative reconstruction(ASIR) to examine the usefulness of image diagnosis.
Materials and methods
CT scans were performed with a 64-slice MIDCT scanner(GE LightSpeed VCT XTe, waukesha, Wisconsin, USA). CTDI measurement was used for comparing doses while the ACR Phantom was used for image quality comparison. The ASIR was used for image reconstruction which create a noise map based on the filtered backprojection(FBP) and organized a statistical model and blends it with appropriately original FBP image. For image quality comparison in phantom study, CTDIVOL 14.76 mGy for non-ASIR was applied and evaluations were clone by analyzing items such as noise level, olv-contrast and high-contrast resolution.
In patient study, test were clone by CTDIVOL 9.45 mGy (standard chest CT dose) and 0.90 mGy, 0.45 mGy, and 0.36 mGy(low dose CT) were delivered with standard and bone kernel.
Results
In phantom study showed that the upward values of spatial resolution were generally similar among kernels and low-resolution kernels showed excellence of contrast to noise(CNR) above 1.0 compared to high-resolution kernels in ASIR 50 and showed improved CNR even though decreased of dose 40% above. With same Parameters noise level(NL) showed 2% in FBP image, 1.5% in ASIR 30% above, and 1% or less in ASIR 100%. Differentiating by the naked eye was difficult, but the differences between each kernel of ASIR were recognized by measuring resolution and noise by quantitative analysis. The effective dose of the low-dose chest examination held as a patient study was only 0.3 mSv or less. It showed reduction of 90% compared to the standard dose, and similar image quality was maintained by applying ASIR 30~60%. However, high-resolution kernels With high ASIR showed a severe level of noise including streak artifacts.
Conclusion
CT image reorganization using ASIR is considered to be a useful dose reducing method while maintaining the image quality, when comparing with the existing filtered back-projection (FBP) reorganized images.
목차
Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
해당간행물 수록 논문
- CT 검사에서 Gantry Aperture의 Isocenter와 피사체 중심의 불 일치 시 선량과 화질의 평가
- CT Guided Interventional Sturdy에서 Conventional Scan Mode 적용에 따른 선량 감소에 관한 연구
- CT실의 환경오염평가와 환경소독에 관한 연구
- Multi-detector Computed Tomography를 이용한 Neck 검사에서 Automatic Exposure Control을 이용한 선량의 최적화
- 폐 소결절 환자를 대상으로 한 CT-guided Wire Marking Procedure에 대한 유용성 평가
- Volume Rendering CT Image의 TACE Reference Data로서의 유용성
- Lumbar Spine Disease 환자의 2D Sagittal Reformation 시 Reformation Angle에 따른 Intervertebral Foramina Image에 대한 고찰
- Adaptive Statistical Iterative Reconstruction 기법의 적용에 따른 Computed Tomography 영상의 화질과 선량 연구
- ECG-gated Cardiac MDCT 검사에서 심장기능 평가를 위한 최적의 수축기말과 확장기말 Phase(%)에 관한 연구
- Multi-detector Computed Tomography에서 환자의 자세 변화에 따른 Esophageal Cancer 진단의 유용성
- Dual Source CT에서 High-pitch Cardiac Scan Mode를 이용한 관상동맥 검사의 유용성
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선사 맞춤형 조영제 정맥주사 교육과정 개발
의약학 > 방사선과학분야 NEW
- 재구성 알고리즘과 Butterworth 필터 차단 주파수가 핵의학 영상 화질에 미치는 영향: Prominence Processor 기반 시뮬레이션 연구
- 합성곱 블록 주의 모듈과 U-Net을 활용한 CT 영상 노이즈 제거 기법
- 요오드 조영제 자동 주입 시 외부 가온기 사용이 온도 변화에 미치는 영향
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!