CT Guided Interventional Sturdy에서 Conventional Scan Mode 적용에 따른 선량 감소에 관한 연구

이용수 19

영문명
The Sturdy for Reduction of Radiation Dose According to Conventional Scan Mode in CT Guided lnterventional Sturdy
발행기관
대한CT영상기술학회
저자명
김지혜(Ji Hye Kim) 김문찬(Moon Chan Kim) 남윤철(Yoon Cheul Nam)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제1호, 87~94쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.04.30
이용가능 이용불가
  • sam무제한 이용권 으로 학술논문 이용이 가능합니다.
  • 이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다. 1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Recently CT guided interventional sturdy applied the helical scan mode which occurred overscanning dose. If you apply conventional scan mode, overscanning dose can be reduced. This sturdy intend to evaluate dose reduction and image quality from applying the protocol in conventional scan mode that decrease overscanning dose. Materials and methods All exams were proceeded on Aquilion 64 of Toshiba and used for ACR and CATPHAN phantom. the average number of pre. San was 1.0±0, scan range was an average of 9.2±2.6 cm in CT guided bone biopsy. the average number of pre. scan was 3.0±1.1, scan range lesion average of 11.1±3.3 cm in CT guided kidney RFA. we scanned repeatedly lesion area inserting the needle into the organ except for pre. scan. 7.2+3.2 times in CT guided bone biopsy, 14.0±5.1 times in CT guided kidney RFA. The conditions of helical scan mode protocol were as followed: 120 kVp, 70 mA, 0.6 sec, 2 mm slice thickness, 8 mm beam collimation, 0.938 pitch, and effective mAs was 45 mAs. to apply same CTDIvol with helical scan mode, the conditions of conventional scan mode were set on 120 kVp, 80 mA, 0.6 sec, 2 mm slice thickness, 8 mm beam collimation. We estimated the effect of dose reduction from effective dose derived from total DLP of conventional scan mode and thar of helical scan mode. ACR and CATVHAN phantom were used for evaluation of image quality. Results The estimate of dose showed total DPL 174.2±51.8 mGyㆍcm, effective dose 3.3±0.9 mSv in conventional scan mode, compared with total DPL 256.6±82.3 mGyㆍcm, effective dose 4.9±1.6 mSv in helical scan mode, which is reduced in 32.1±3.9% in CT guided bone biopsy. In CT guided kidney RFA, total DPL 465.3±139.7 mGyㆍcm, effective dose 7.0±2.0 mSv in conventional scan mode, compared with total DPL 647.5±200.6 mGyㆍcm, effective dose 9.7±3.0 mSv in helical scan mod, which is reduced in 29.1±6.8%. The result of noise is 15.4 HU in helical scan mode and 21.9 HU in conventional scan mode which is 6.5 HU higher d1an helical scan mode but almost did nor affect the image quality. Conclusion Accordingly, in conventional scan mode the ration of dose reduction was approximately 29.1~32.1% clue to decreased overscanning dose and the risk of stochastic effects and deterministic effects was not found in CT guided interventional sturdy. Therefore, we should sturdy more minimize dose for the patient while maintaining image quality through using optimal protocol.

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김지혜(Ji Hye Kim),김문찬(Moon Chan Kim),남윤철(Yoon Cheul Nam). (2010).CT Guided Interventional Sturdy에서 Conventional Scan Mode 적용에 따른 선량 감소에 관한 연구. 대한CT영상기술학회지, 12 (1), 87-94

MLA

김지혜(Ji Hye Kim),김문찬(Moon Chan Kim),남윤철(Yoon Cheul Nam). "CT Guided Interventional Sturdy에서 Conventional Scan Mode 적용에 따른 선량 감소에 관한 연구." 대한CT영상기술학회지, 12.1(2010): 87-94

sam 이용권 선택
님이 보유하신 이용권입니다.
차감하실 sam이용권을 선택하세요.