CT 검사에서 Gantry Aperture의 Isocenter와 피사체 중심의 불 일치 시 선량과 화질의 평가

이용수  294

영문명
Evaluation of Dose and Image Quality in Case of Discordance Between Isocenter of Gantry Aperture and Object Center in CT Examination
발행기관
대한CT영상기술학회
저자명
이밈영(Min Yung Lee) 김문찬(Moon Chan Kim) 남윤철(Yoon Chul Nam) 한동균(Dong Kyoon Han)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제1호, 79~86쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose To recognize thar exact adjustment of the table’s vertical center is important in CT examination by analyzing the dose effect and image quality in case of discordance between isocenter of gantry aperture and object center in CT examination. Materials and methods 32 cm body phantom with pencil type CT ionization chamber was used to measure CTDI, and Rando phantom with glass dosimetry was used to measure organ dose. Also, ACR phantom was used to analyze image quality at GE LightSpeed VCT XT 64 MDCT. Dose and image quality were checked at off-centering of each 30 mm, 60 mm lower in the vertical direction, compared with center in the isocenter of gantry aperture. CTDI was measured at 4 position(12, 9, 6, 3 o’clock) of same plane in each vertical direction levels. And organ doses were measured ar both chest CT and abdomen CT with and without AEC. Measured organ were thyroid, breast, heart, lung in chest CT and liver, kidney, uterus, gonad in abdominal CT. Analysis of image quality was done by evaluating objective noise, low contrast resolution, high contrast resolution and uniformity under the condition of clinical abdominal study protocol. Results 1. DTDI value ar die position of 12 o’clock in the phantom was increased according to lower object, while CTDI values at die position of 3, 6, 9 o’clock were decreased. 2. When object was positioned at lower levels in chest CT and abdomen CT with AEC, all organ doses were decreased. 3. Breast and heart doses were increased at lower levels dian gantry isocenter in chest CT without AEC. 4. CT No. of water, low contrast resolution, high contrast resolution, uniformity were our of standard range according to off-centering of object. Conclusion Incorrect patient’s position can affect dose and image quality due to varied noise index value presetted by bow-tie filter in using AEC technology and increase surface dose to sensitive organ such breast. Therefore, it is always need for centering object to isocenter of gantry aperture precision with the greatest care.

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이밈영(Min Yung Lee),김문찬(Moon Chan Kim),남윤철(Yoon Chul Nam),한동균(Dong Kyoon Han). (2010).CT 검사에서 Gantry Aperture의 Isocenter와 피사체 중심의 불 일치 시 선량과 화질의 평가. 대한CT영상기술학회지, 12 (1), 79-86

MLA

이밈영(Min Yung Lee),김문찬(Moon Chan Kim),남윤철(Yoon Chul Nam),한동균(Dong Kyoon Han). "CT 검사에서 Gantry Aperture의 Isocenter와 피사체 중심의 불 일치 시 선량과 화질의 평가." 대한CT영상기술학회지, 12.1(2010): 79-86

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제