- 영문명
- The Usefulness of Volume Rendered Computed Tomographic Image as Reference Data for Transcatheter Arterial Chemoembolization
- 발행기관
- 대한CT영상기술학회
- 저자명
- 한성일(Seong Il Han) 나상훈(Sang Hun Na) 김종옥(Jong Ok Kim) 이제호(Jae Ho Lee) 김성배(Seong Bae Kim)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제1호, 53~58쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2010.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose
Transcatheter arterial chemoembolization(TACE) have a treating objective by inserting the angiography catheter in the hepatic artery that supplies blood to the hepatocellular carcinoma(HCC) and by this it can mix up the injection of carcinostatis and embolus substances to necrosis the liver cancer organisms. Typically a computed tomography(CT) decoding result was used as a treating plan by the doctor before transcatheter arterial chemoembolization was preceded but because of false classifications and the increased time of surgical operations, the anti-cancer medicine can be used in places that are not needed which bring out great pains to the patients. This investigation has been made so that confusions can be decreased when using the vascular volume rendering data that has been created in the 3 dimensional-lab.
Materials and methods
From a total of 1,144 cases that has used TACE at the National Cancer Center from June 1st, 2008 to August 5th, 2009, 50 HCC patients(43 men, 7 women with the average age being 58.18 years old ranging from 34 to 78 years) that converted their examined liver dynamic computed tomography’s artery phase image to a volume rendering image were evaluated by two decoding doctors and one radiologic technologist.
Results
The investigated patients were classified into four types. Type 1 was decoded that there was each lesion in the segment 5 through the segment 8 of the right lobe of liver according to CT test, but there was a lesion in other segment in case of TACE procedure. In other words, it meant that the segmentation was different in the right volume of liver. Type 2 was decoded that there was a lesion in the segment 4 according to CT test, but there was a lesion in the segment 8 in case of TACE procedure. In other words, is meant that the segmentation was different in the liver dome. Type 3 was decoded mat there was a lesion in me multiple segments or the single segment according to CT test, but there was a lesion in the single segment or the multiple segments in case of TACE procedure. And type 4 was the case that the results of decoding cannot be same or different in CT test and TACE procedure.
Conclusion
The hepatic artery’s shape in anterio-posterior conditions and the hepatic artery in right anterio-oblique Md left anterio-oblique conditions showed a significant difference. The blood vessels that seemed to be reiterated in AP conditions could be clearly classified by the change of angles in the right anterio-oblique and left anterio-oblique.
목차
Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
해당간행물 수록 논문
- CT 검사에서 Gantry Aperture의 Isocenter와 피사체 중심의 불 일치 시 선량과 화질의 평가
- CT Guided Interventional Sturdy에서 Conventional Scan Mode 적용에 따른 선량 감소에 관한 연구
- CT실의 환경오염평가와 환경소독에 관한 연구
- Multi-detector Computed Tomography를 이용한 Neck 검사에서 Automatic Exposure Control을 이용한 선량의 최적화
- 폐 소결절 환자를 대상으로 한 CT-guided Wire Marking Procedure에 대한 유용성 평가
- Volume Rendering CT Image의 TACE Reference Data로서의 유용성
- Lumbar Spine Disease 환자의 2D Sagittal Reformation 시 Reformation Angle에 따른 Intervertebral Foramina Image에 대한 고찰
- Adaptive Statistical Iterative Reconstruction 기법의 적용에 따른 Computed Tomography 영상의 화질과 선량 연구
- ECG-gated Cardiac MDCT 검사에서 심장기능 평가를 위한 최적의 수축기말과 확장기말 Phase(%)에 관한 연구
- Multi-detector Computed Tomography에서 환자의 자세 변화에 따른 Esophageal Cancer 진단의 유용성
- Dual Source CT에서 High-pitch Cardiac Scan Mode를 이용한 관상동맥 검사의 유용성
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선사 맞춤형 조영제 정맥주사 교육과정 개발
의약학 > 방사선과학분야 NEW
- 재구성 알고리즘과 Butterworth 필터 차단 주파수가 핵의학 영상 화질에 미치는 영향: Prominence Processor 기반 시뮬레이션 연구
- 합성곱 블록 주의 모듈과 U-Net을 활용한 CT 영상 노이즈 제거 기법
- 요오드 조영제 자동 주입 시 외부 가온기 사용이 온도 변화에 미치는 영향
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!