본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

멀티 플라즈마 반응기를 이용한 E. coli 소독

이용수  17

영문명
E. coli Disinfection Using a Multi Plasma Reactor
발행기관
한국환경보건학회
저자명
김동석(Dong-Seog Kim) 박영식(Young-Seek Park)
간행물 정보
『한국환경보건학회지』제39권 제2호, 187~195쪽, 전체 9쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
2013.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and UV254 absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, UV254 absorbance, and E. coli disinfection with the plasma process were better than with the UV process.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김동석(Dong-Seog Kim),박영식(Young-Seek Park). (2013).멀티 플라즈마 반응기를 이용한 E. coli 소독. 한국환경보건학회지, 39 (2), 187-195

MLA

김동석(Dong-Seog Kim),박영식(Young-Seek Park). "멀티 플라즈마 반응기를 이용한 E. coli 소독." 한국환경보건학회지, 39.2(2013): 187-195

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제