본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Comparison of Physical Properties of Polypropylene Sutures and Knot Method to Prevent the Slippage of Sutured Scleral Fixation

이용수  0

영문명
발행기관
대한검안학회
저자명
Yeon Hee Choi Min Ho Kang
간행물 정보
『Annals of optometry and contact lens』Vol.23 No.4, 178~183쪽, 전체 6쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2024.12.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Purpose: This study compared the physical properties of 9-0 and 10-0 polypropylene sutures used in scleral-sutured posterior chamber intraocular lens (PCIOL) fixation, with a focus on knot security and methods to prevent slippage. Methods: Tensile strength measurements were performed on 10-0 and 9-0 polypropylene sutures (Prolene™) using a material testing machine (Instron 5966 Load Frame, Model 2701-065 controller; Instron Corp., Norwood, MA). Various knotting techniques were evaluated, including a single fisherman’s knot and one, three, and five overhand knots tied around the haptic of a three-piece IOL. Knot thickness and area of the surgeon’s Knot were measured using microscopy and Image J® software, with statistical analysis conducted to compare the differences between the two suture types. Results: The 9-0 polypropylene sutures exhibited a significantly higher maximum tensile strength than the 10-0 sutures, particularly with a single fisherman’s knot (0.47 N vs. 0.52 N, p = 0.007; 0.27 N vs. 0.50 N, p < 0.001). However, when multiple overhand knots were tied around the haptic, the 10-0 sutures showed increased tensile strength with more knots (0.11 N, 0.23 N, 0.33 N, p < 0.05), whereas the 9-0 sutures did not (0.06 N, 0.31 N, 0.19 N). Notably, three overhand knots provided better stability than five knots (p < 0.05). The knot area and thickness of the surgeon’s knot were significantly larger in the 9-0 sutures than in the 10-0 sutures (21,062.4 μm2 vs. 41,188.5 μm2, p < 0.001; 160.1 μm vs. 195.6 μm, p = 0.021). Conclusions: Overhand knots increased friction between the suture and IOL haptic, enhancing knot security. However, in the 9-0 sutures, the higher rigidity caused the knots to loosen more easily, decreasing the tensile strength with more knots. This study suggests that three overhand knots are optimal for securing IOL haptics using both 9-0 and 10-0 sutures.

영문 초록

목차

INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Yeon Hee Choi,Min Ho Kang. (2024).Comparison of Physical Properties of Polypropylene Sutures and Knot Method to Prevent the Slippage of Sutured Scleral Fixation. Annals of optometry and contact lens, 23 (4), 178-183

MLA

Yeon Hee Choi,Min Ho Kang. "Comparison of Physical Properties of Polypropylene Sutures and Knot Method to Prevent the Slippage of Sutured Scleral Fixation." Annals of optometry and contact lens, 23.4(2024): 178-183

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제