핵의학과에서 99mTc를 이용한 방사성의약품의 투여율 측정 비교
이용수 32
- 영문명
- Comparison of the Measurement of the Injection Rate of Radioactive Drugs Using 99mTc in Nuclear Medicine
- 발행기관
- 대한방사선과학회(구 대한방사선기술학회)
- 저자명
- 손상준(Son Sang-Joon) 박정규(Park Jeong-Kyu) 정동경(Jung Dong-Kyung) 박명환(Jung Dong-Kyung)・ Park Myeong-Hwan)
- 간행물 정보
- 『방사선기술과학』방사선기술과학 제43권 제2호, 97~103쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2020.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
This study was conducted by SPECT test at the Department of Nuclear Medicine at Daegu P Hospital from June 1 to October 31, 2019. A 3-way injection material was mounted among inpatients, and a syringe that was administered with radiopharmaceuticals using a 99mTc labeled compound was secured. We tried to find a way to calculate the dose rate of each radiopharmaceutical and increase the dose rate. As a result of measuring the radioactivity of radiopharmaceuticals using 99mTc, the average dose rate of 60 syringes of all 6 radiopharmaceuticals was 93.26±7.34%, and the average dose rate of 99mTc-DMSA was 77.72%, 15.54% lower than the total. As a way to increase the dosing rate, the average dose rate diluted twice with the remaining amount of syringe after administration using normal saline increased to 95.37±6.99%, and the average dose rate diluted three times increased to 96.32±6.86%. The corresponding sample t-test to compare the pre- and post-dose rates at 1 dilution and 2 and 3 dilutions. As a result of the dilution and 2 dilutions, the probability of significance was 0.013, which was significantly higher than the dilution(p<0.05). The probability of significance for dilution 1 and dilution 3 was 0.016, which was significantly higher than in one dilution(p<0.05). The sum of the average dose rate using the experimental 3-way line was the highest with 98.85±1.42% of 99mTc, 99mTc-ECD 98.82±1.26%, 99mTc-Mebrofenin 98.82 ± 1.16%, 99mTc-HDP 98.74 ± 1.91%, 99mTc -MIBI was 98.69 ± 1.48%, and 99mTc-DMSA was the lowest with 86.47 ± 4.74%. When the number of dilutions was 5 times using 0.5 cc of normal saline and when the number of dilutions was 5 times using 1 cc of normal saline, when the number of dilutions was 5 times using 0.5 cc of normal saline and 1 cc of nomal saline When the number of dilutions was 5 times and the syringe volume was 0.5 cc, there was a statistically significant difference (p<0.05). There was a statistically significant difference when the number of dilutions was 5 times using 1 cc of nomal saline and the number of dilutions was 5 times using 1 cc of normal saline, and the syringe volume was 0.5 cc (p<0.05).
목차
Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
키워드
해당간행물 수록 논문
- 흉부 방사선영상의 좌, 우 반전 발생 여부 컨벌루션 신경망 기반 정확도 평가
- 핵의학과에서 99mTc를 이용한 방사성의약품의 투여율 측정 비교
- 디지털 방사선 영상의 편차지수를 이용한 의료영상 품질관리에 관한 연구
- 초음파 탐촉자의 위생관리에 관한 연구
- Standard와 MAR 알고리즘에서 CT 검사조건 변화에 따른 인공물과 노이즈 평가
- 가공제품에 대한 생활주변방사선 실태조사 자료를 활용한 통계분석
- 동일 기종 선형가속기간 8 MV 광자선에 대한 빔 매칭 정확도 평가
- 코로나바이러스감염증-19 상황에서 일개 국가지정 의료기관의 이동형 병원 CT 활용 사례
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 무증상 치밀 유방 여성에서 인공지능 기반 컴퓨터 보조 진단 장치의 유용성 연구
- 방사선치료 임상실습 환경에 따른 방사선(학)과 학생의 학습 효과 분석
- 딥러닝을 활용한 한국형 유방초음파 영상 정상-종괴 구분 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!