조영제와 생리식염수 주입 순서에 의한 Syringe내에서의 CT Number값 변화

이용수  55

영문명
The change of CT Number in the sylinge by pouring order of the Contrast Medium and Saline
발행기관
대한CT영상기술학회
저자명
김도훈(Do Hun Kim) 김기홍(Ki Hong Kim) 정재연(Jae Yeon Chung) 조현종(Hyeon Jong Cho)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제9권 제1호, 145~148쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2007.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose A lot of hospitals use Contrast Medium mixed with Normal Saline when they operate CT study. This brings about cut down in expenditures as well as reduction of artifact in Subclavian vein. This thesis try to mearsure CT Number in the syringe when they were used mixed clinically, and to come up with right method of using those Contrast Medium, and Normal Saline. Materials and Methods We used the same materials and equipment as an actual CT Study. We used UltraVist300 as Contrast Medium, NaCl 0.9% for Normal Saline, and the ratio of Contrast Medium and Normal Saline is 1:1, 1:2, and 2:1 respectively. At the experiment, we measured CT Number in 200ml-syringe and measured the changed of CT Number for ten minutes, which is similar amount of time as the actual experiment. We used SIEMENS Somatom Sensation 16, and measured with Sequence Mode lOmm. ROI was 1cm/sq at the measurement. To distinguish Normal Saline from Contrast Medium, we put 1ml of blue ink into Normal Saline. Results At the Chest examination, it is beuer to pour Contrast Medium first and then Normal Saline later. When we put Normal Saline first and Contrast Medium later, it is diluted by just pouring them together. At all the experiments, when turned upside down, it shows the sTable distribution. At all the experiments, the CT Number show the highest at the lowest level. Conclusion We have checked CT Number in the syringe when we had experiment using Contrast Medium adding Normal Saline. Through this experiment, we could find out the mixed degree of Contrast Medium and Normal Saline that had been able to be checked only by naked eyes. Based on the results above, it is expected to apply it in an appropriate density. At the future research, based on the result above, I would like to find out the ideal CT Scan Start Time when the Artifact comes th the least at Image by finding out the time Contrast Medium is poured into Subclavian vein with flow rate, total volume of Contrast Medium and Normal Saline and the pouring pressure.

목차

Abstract
Ⅰ. 목적
Ⅱ. 실험 재료 및 방법
Ⅲ. 실험결과
Ⅳ. 결론 및 고찰
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김도훈(Do Hun Kim),김기홍(Ki Hong Kim),정재연(Jae Yeon Chung),조현종(Hyeon Jong Cho). (2007).조영제와 생리식염수 주입 순서에 의한 Syringe내에서의 CT Number값 변화. 대한CT영상기술학회지, 9 (1), 145-148

MLA

김도훈(Do Hun Kim),김기홍(Ki Hong Kim),정재연(Jae Yeon Chung),조현종(Hyeon Jong Cho). "조영제와 생리식염수 주입 순서에 의한 Syringe내에서의 CT Number값 변화." 대한CT영상기술학회지, 9.1(2007): 145-148

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제