본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

관상동맥 협착 진단을 위한 workstation별 QCA값의 비교 평가

이용수  19

영문명
A Comparison on QCA Values Based on the Workstations for Diagnosing Coronary Arteriostenosis
발행기관
대한CT영상기술학회
저자명
김완역(Wan Yuk Kim) 박건진(Kun Jin Park) 변정인(Jung In Byun)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제9권 제1호, 91~97쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2007.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose As 64 Multi-Detector Computed Tomography systems were recently introduced and software has been variously developed, coronary CT angiography has been clinically come into notice. The patients, diagnosed with coronary arteriostenosis due to thrombi, were subject to this study. In this study, Quantitative Coronary Analysis value was comparatively analyzed by using the workstations produced by 4 companies respectively. Materials and Methods The 20 patients who showed the stenos is of the left anterior descending artery due to thrombi, among the patients, who underwent coronary CT angiography from November 2006 until January 2007, were subject to this study. The CT angiography was performed by using Toshiba Aquilion 64 under the condition of 120kVp, 400mA, 0.4sec tube rotation time. In result, the images of 75, 35, 45 and 90% with the sectional thickness of 0.5mm/0.4mm were taken and were transmitted to the workstation for image reconstruction. Extended brilliance workstation, Advantage workstation, Vitrea workstation, and TeraRecon workstation were used to measuring instruments, and QCA value, i.e., the stenos is degree of left anterior descending artery, was measured. Results 1. With regard to the QCA value based on area value, TeraRecon workstation showed the highest value but the value of PDW was lowest. 2. With regard to the QCA value based on average diameter value, the value of Vitrea workstation was highest but ADW also showed the lowest value. Conclusion QCA values were measured by using the workstations produced by 4 companies respectively; with the consequence that the values become different as to company and TeraRecon workstation and Vitrea workstation did not show conspicuous differences in case the vascular diameter is over 3mm. However, EBW and ADW showed remarkable differences in case the vascular diameter is less than 3mm. In case the vascular area is over 6mm², TeraRecon workstation and Vitrea workstation did not significant differences. When compared to QCA, the ability of workstation to quantitatively assess coronaiy artery diameters and coronary artery stenases is insufficient for clinical purposes

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김완역(Wan Yuk Kim),박건진(Kun Jin Park),변정인(Jung In Byun). (2007).관상동맥 협착 진단을 위한 workstation별 QCA값의 비교 평가. 대한CT영상기술학회지, 9 (1), 91-97

MLA

김완역(Wan Yuk Kim),박건진(Kun Jin Park),변정인(Jung In Byun). "관상동맥 협착 진단을 위한 workstation별 QCA값의 비교 평가." 대한CT영상기술학회지, 9.1(2007): 91-97

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제