Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance (162.72±42.55 N), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.

목차

Abstract
I. Introduction
II. Materials and Methods
III. Results
IV. Discussion
V. Conclusion
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Zarina Tatia Barbosa Vieira Santos,Douglas Rangel Goulart,Eder Alberto Sigua Rodriguez,Leandro Pozzer,Sergio Olate,José, Ricardo Albergaria Barbosa. (2017).Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy. 대한구강악안면외과학회지, 43 (2), 77-82

MLA

Zarina Tatia Barbosa Vieira Santos,Douglas Rangel Goulart,Eder Alberto Sigua Rodriguez,Leandro Pozzer,Sergio Olate,José, Ricardo Albergaria Barbosa. "Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy." 대한구강악안면외과학회지, 43.2(2017): 77-82

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제