학술논문
Reliability and Validity of Measurement of Infrasternal Angle by Radiographic Methods
이용수 0
- 영문명
- Reliability and Validity of Measurement of Infrasternal Angle by Radiographic Methods
- 발행기관
- KEMA학회
- 저자명
- Won-hwee Lee
- 간행물 정보
- 『Journal of Musculoskeletal Science and Technology』제2권 제2호, 33~37쪽, 전체 5쪽
- 주제분류
- 의약학 > 재활의학
- 파일형태
- 발행일자
- 2018.12.31
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Background The infrasternal angle is typically measured using goniometric or photographic methods. Because chest anterior–posterior radiographic images cannot be used to identify the xiphoid process, no study has evaluated the validity of infrasternal angle measurement. Purpose The purpose of this study was to determine reliability and validity of measurement of infrasternal angle by radiographic method. Study design Intra- and inter-tester repeated measures. Methods Infrasternal angles were measured in 25 healthy students using goniometric and radiographic method. To check the xiphoid process in radiographs, the examiner set the marker at the xiphoid process. Radiographs were taken by one X-ray technician for each subject using a radiographic apparatus. Repeated radiographs measurements were made in two test sessions conducted on different days by two testers to assess inter-rater and intra-rater reliability. The reliability of the infrasternal angle measurement was using intraclass correlation coefficients (ICCs: 3,1). The correlation between measurements taken by the radiograph and goniometric methods was calculated to test the validity of the radiographic method. The alpha level was set at 0.05. Results The intra- and inter-rater reliability of infrastenral angle measurements taken by the radiographic method were excellent (ICC=0.991 and 0.993, respectively). Radiographic measurement of the infrasternal angle was highly correlated with goniometric measurement (r= 0.85). Conclusions We suggest that the radiographic method is a highly reliable and valid tool for infrasternal angle measurement.
목차
INTRODUCTION
METHODS
RESULTS
DISCUSSION
CONCLUSIONS
REFERENCES
해당간행물 수록 논문
- Reliability and Validity of Measurement of Infrasternal Angle by Radiographic Methods
- A Movement-System-Impairment Approach to the Evaluation and Treatment of a Patient with Femoral Anterior Glide Syndrome: A Case Report
- Elaborate Corrective Exercise Program after Surgical Correction for Sprengel’s Deformity: A Case Study
- A Movement-System-Impairment Approach to the Evaluation and Treatment of a Patient with Piriformis Syndrome: A Case Report
- Isolated Activation of the Infraspinatus Muscle in Four Manual Muscle Testing Positions
- Relationship of Scratch Test and Glenohumeral Internal Rotation and Horizontal Adduction Range of Motion
참고문헌
관련논문
의약학 > 재활의학분야 BEST
- 중증정신질환자가 이용하는 지역사회 정신건강서비스에 대한 체계적 고찰
- 인지행동치료가 조현병 환자의 자아존중감에 미치는 영향에 대한 체계적 고찰
- 정신건강분야에서의 ICF 관련 연구 동향
의약학 > 재활의학분야 NEW
- 불안 수준에 따른 노인 운전자의 운전 상황별 운전 효능감: 정신건강 운전재활 전문서비스의 필요성 관점으로
- 남성과 여성 노인의 여가활동이 우울에 미치는 영향
- 정신건강 증진 및 정신질환자 복지서비스 지원에 관한 법률 개정에 따른 정신건강 작업치료 연구동향 분석
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
