본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

핵의학 침샘 검사 시 동적 및 정적 검사 방법에서의 분비 계수에 대한 비교

이용수  0

영문명
Comparative Analysis of Dynamic and Static Salivary Gland Scintigraphy Using Ejection Fraction
발행기관
대한핵의학기술학회
저자명
전기웅(Gi-Woong Jun) 김영빈(Young-Bin Kim)
간행물 정보
『핵의학기술』Vol.29 No.1, 45~52쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2025.05.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Purpose: This study aims to compare the ejection fraction (EF%) values derived from static and dynamic salivary gland scintigraphy and assess whether there are statistically significant differences between the two imaging techniques. Materials and Methods: Thirty patients (10 males, 20 females; mean age: 65.9 years) complaining of xerostomia underwent dynamic salivary scintigraphy with 185 MBq (5 mCi) of 99mTc-pertechnetate. Imaging was performed using a Discovery NM630 gamma camera (GE Healthcare, USA). Vitamin C powder (2 g) was administered as a stimulant at 40 minutes after radiotracer injection. Dynamic images were acquired at 60-second intervals for 50 minutes. Static images were reconstructed by summing specific frame sets pre- and poststimulation. Ejection fraction was calculated using the Xeleris Functional Imaging Workstation (GE Healthcare, USA), with regions of interest applied to the right parotid and submandibular glands. Statistical analysis was conducted using paired t-tests and correlation coefficients. Results: The ejection fraction average was 81.94±7.94% when calculated using a dynamic method and 80.94±7.95% when calculated using a static method, which was larger when calculated using a dynamic method by a difference of 0.99±3.21% and the correlation was 0.918, and there was no statistically significant difference(P > 0.05). Conclusion: The scan time and equipment operation time are different according to the dynamic and static methods, and each method has advantages and disadvantages. As designating the stimulation time or image composition time, there was a limitation in deriving results according to retrospective analysis, but in this study, since there is no significant difference in the ejection fraction according to method, it is considered that the scan will proceed more efficiently if a more efficient method is selected and used for each laboratory according to the situation among the two methods.

영문 초록

목차

서론
대상 및 방법
결과
고찰
결론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

전기웅(Gi-Woong Jun),김영빈(Young-Bin Kim). (2025).핵의학 침샘 검사 시 동적 및 정적 검사 방법에서의 분비 계수에 대한 비교. 핵의학기술, 29 (1), 45-52

MLA

전기웅(Gi-Woong Jun),김영빈(Young-Bin Kim). "핵의학 침샘 검사 시 동적 및 정적 검사 방법에서의 분비 계수에 대한 비교." 핵의학기술, 29.1(2025): 45-52

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제