학술논문
지연된 인슐린 검사에서 검체 보관 방법의 영향에 대한 고찰
이용수 0
- 영문명
- Impact of Delayed Sample Separation and Storage Conditions on Insulin Stability
- 발행기관
- 대한핵의학기술학회
- 저자명
- 곽지종(Ji Jong Kwak) 고희영(Hee Young Go) 김성수(Seongsu Kim) 이남주(Nam Ju Lee)
- 간행물 정보
- 『핵의학기술』Vol.29 No.1, 15~21쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2025.05.31
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
Purpose: Insulin assays are highly sensitive to pre-analytical handling issues. While numerous studies have reported that the stability of insulin in non-hemolyzed samples is affected by time and temperature, there is limited information regarding the impact of delayed sample separation. Although research on this topic using the electrochemiluminescence immunoassay (ECLIA) method is actively conducted both domestically and internationally, studies utilizing the immunoradiometric assay (IRMA) are primarily performed abroad. Therefore, this study aimed to evaluate the stability of insulin in response to delayed separation of primary samples and storage conditions of secondary samples using the IRMA method. Subjects and Methods: The study included a total of 21 participants. Blood samples were processed and stored under different conditions to create serum and plasma samples divided into three groups. Group A: Secondary samples were stored at room temperature for 5 hours and at 2-8 °C for 48 hours. Group B: Secondary samples were stored at 2-8 °C for 5 hours and at -24 °C for 48 hours. Group C: Primary samples were stored at room temperature for 5 hours and at 2-8 °C for 48 hours before separation. Insulin concentrations in each group were measured using the IRMA method. The measured values were compared to insulin concentrations from secondary samples separated immediately after blood collection. The stability of insulin concentrations in each group was evaluated using regression analysis and the Wilcoxon signed-rank test for non-parametric paired sample comparisons. Statistical analysis was performed with MedCalc software (ver. 22.063), and a p-value of <0.05 was considered statistically significant. Results: The serum samples separated after storing the primary samples at 2-8 °C for 48 hours showed a positive correlation coefficient of 0.9974. However, the percentage deviation was -19.35%, and the p-value was <0.05, indicating a statistically significant difference. Similarly, for plasma samples stored as secondary samples at 2-8 °C for 5 hours and 48 hours, the correlation coefficients were 0.9803 and 0.9944, respectively, showing positive correlations. However, the percentage deviations were -7.45% and -6.32%, with p-values of <0.05 for both, demonstrating statistical significance. Conclusion: This study evaluated the stability of insulin assays under various conditions of delayed sample separation and storage methods. It is recommended that insulin assays be performed immediately after blood collection by promptly centrifuging and separating the samples. When storage is necessary, it is crucial to store samples in a separated state. Serum samples were stable when stored at room temperature or at 2-8 °C for 5 hours, and stability was maintained even after 48 hours of storage at 2-8 °C or -24 °C. However, delayed sample separation may result in significant differences in test values, emphasizing the need for careful handling and storage of samples.
영문 초록
목차
서론
대상 및 방법
결과
고찰
결론
REFERENCES
해당간행물 수록 논문
- Abnormal Finding of Left Femoral Bone Mineral Densitometry
- 핵의학 검체검사의 경고치 보고(Critical Value Report)에 관한 실태 조사 보고
- Lu-177 Dotatate SPECT/CT 검사에서 재구성 조건 변화에 따른 영상 질 평가에 관한 연구
- 지연된 인슐린 검사에서 검체 보관 방법의 영향에 대한 고찰
- 25-OH-vitamin D3 RIA 시약별 결과값 비교분석 및 유효성 평가
- 전신 뼈 검사에서 주사 후 영상획득 시간에 따른 뼈와 연부조직에서의 대조도 비교 평가
- 핵의학 침샘 검사 시 동적 및 정적 검사 방법에서의 분비 계수에 대한 비교
- 18F-FES PET/CT 스캔의 임상 적용과 18F-FDG PET/CT 영상 간의 SUVmax 차이 분석
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선학과 학생 실습환경에 관한 연구: 실습실 내 미세먼지, 휘발성유기화합물 위해도를 중심으로
의약학 > 방사선과학분야 NEW
- Abnormal Finding of Left Femoral Bone Mineral Densitometry
- 핵의학 검체검사의 경고치 보고(Critical Value Report)에 관한 실태 조사 보고
- Lu-177 Dotatate SPECT/CT 검사에서 재구성 조건 변화에 따른 영상 질 평가에 관한 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
