Long-term Outcome and Related Risk Factors in Implantable Collamer Lens Implantation of High Myopia

이용수  0

영문명
발행기관
대한안과학회
저자명
Yong Hee Kim Chang Ho Yoon Mee Kum Kim
간행물 정보
『The Korean Journal of Ophthalmology』Vol.39 No.2, 134~144쪽, 전체 11쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2025.04.30
4,120

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Purpose: To investigate the long-term efficacy and safety of posterior chamber implantable collamer lens (ICL) implantation in high myopia, and the risk factors associated with endothelial cell loss (ECL) or cataract development. Methods: Medical records of 66 eyes of 37 patients who underwent ICL implantation for high myopia were retrospectively analyzed with a mean follow-up of 12 years. Changes in best-corrected visual acuity (logarithm of the minimum angle of resolution), intraocular pressure (IOP), refractive power, and endothelial cell density over time were analyzed with the incidence of cataract and IOP elevation. Risk factors were analyzed for their association with ECL or cataract development. Results: At 10 years after surgery, the mean uncorrected visual acuity was 0.06 and the spherical equivalent was –0.90 diopters. By year 10, cataract was present in 13 of 66 eyes (19.7%), whereas glaucoma was found in 1 of 66 eyes (1.5%). Although IOP continuously elevated over time (p < 0.05), it remained within normal limits. The cataract group had a lower vault of ICL and a higher mean age at surgery (p < 0.05). Endothelial cell density remained above 2,000/mm2 in 98.5% of cases, with an average annualized rate of decline of 1.13%. The high annualized rate group (>1.13% loss per year) had a lower mean age than in the low annualized rate group (<1.13% loss per year, p < 0.05). Conclusions: This indicates that ICL implantation is effective for high myopia, and its main complication is cataract and ECL. It also suggests that ECL and cataract should be regularly monitored although ECL looks stable in long-term follow-up. Age may affect both ECL and cataract, while low-vault ICL may affect cataract.

영문 초록

목차

Materials and Methods
Results
Discussion
Supplementary Materials
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Yong Hee Kim,Chang Ho Yoon,Mee Kum Kim. (2025).Long-term Outcome and Related Risk Factors in Implantable Collamer Lens Implantation of High Myopia. The Korean Journal of Ophthalmology, 39 (2), 134-144

MLA

Yong Hee Kim,Chang Ho Yoon,Mee Kum Kim. "Long-term Outcome and Related Risk Factors in Implantable Collamer Lens Implantation of High Myopia." The Korean Journal of Ophthalmology, 39.2(2025): 134-144

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제