본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Reliability and Accuracy of Smart Eye Camera in Determining Grading of Nuclear Cataract

이용수  33

영문명
발행기관
대한안과학회
저자명
Anak Agung Mas Putrawati Triningrat Angelo Doniho Wayan Gede Jayanegara I Gde Raka Widiana Siska Wigono Ni Made Laksmi Utari Eisuke Shimizu Shintaro Nakayama Thendy Foraldy
간행물 정보
『The Korean Journal of Ophthalmology』Vol.39 No.2, 114~124쪽, 전체 11쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2025.04.30
4,120

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Purpose: Cataracts are the cause of more than 50% of blindness in the world. Cataract is diagnosed using a slit lamp to evaluate the opacity of the lens. Slit lamps as the primary tools cataract are not available in primary care units. Smart Eye Camera (SEC) is a medical device placed on smartphone, capable of creating slit beam similar to conventional slit lamp. Previous studies have been conducted in Japan. We wanted to further compare ocular examination between SEC and conventional slit lamp with samples taken from UPTD Eye Clinic Ambon Vlissingen in Indonesia. Methods: Observational analytical study with a cross-sectional study design. The research sample consisted of 67 people selected by consecutive sampling. All samples were examined for cataracts using a conventional slit lamp and SEC. To evaluate the accuracy of SEC, diagnosis of cataract was carried out by one observer based on slit-lamp images. The results of examinations were then compared with the examinations by two observers based on the SEC video, where the videos were read two times in a span of 1 week. Results: Sixty-seven eye samples were taken with average age of 61.76 ± 5.83 years, visual acuity was 0.07 ± 0.12, intraocular pressure was 14.12 ± 2.06 mmHg, and SEC video duration was 4.15 ± 1.09 seconds. SEC intraobserver reliability has a κ of 0.795/0.818, SEC interobserver reliability has a κ of 0.795/0.817. SEC assessment accuracy for observer 1 has a κ of 0.606/0.681 and for observer 2 has a κ of 0.629/0.717, with the highest accuracy for cataract grade 3 (86.67% and 91.18%, respectively). Conclusions: This study shows SEC has good consistency and reliability in assessing the degree of nuclear cataract compared to conventional slit lamp. This tool could be used for cataract screening in remote areas.

영문 초록

목차

Materials and Methods
Results
Discussion
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Anak Agung Mas Putrawati Triningrat,Angelo Doniho,Wayan Gede Jayanegara,I Gde Raka Widiana,Siska Wigono,Ni Made Laksmi Utari,Eisuke Shimizu,Shintaro Nakayama,Thendy Foraldy. (2025).Reliability and Accuracy of Smart Eye Camera in Determining Grading of Nuclear Cataract. The Korean Journal of Ophthalmology, 39 (2), 114-124

MLA

Anak Agung Mas Putrawati Triningrat,Angelo Doniho,Wayan Gede Jayanegara,I Gde Raka Widiana,Siska Wigono,Ni Made Laksmi Utari,Eisuke Shimizu,Shintaro Nakayama,Thendy Foraldy. "Reliability and Accuracy of Smart Eye Camera in Determining Grading of Nuclear Cataract." The Korean Journal of Ophthalmology, 39.2(2025): 114-124

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제