Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of ¹⁸F-FDG (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned ¹⁸F-FDG PET/CT and also received care through the tracking test (mean age 55.61±12.41 years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value= 0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A . It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using ¹⁸F-FDG, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.
목차
서론
실험재료 및 방법
결과
고찰 및 결론
요약
REFERENCES
해당간행물 수록 논문
- 인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화
- 식도암 환자의 GET 영상 평가
- PET/CT 검사에서 2024-04-08¹⁸F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰
- (n,γ)⁹⁹Mo를 이용한 ⁹⁹Mo-99mTc발생기의 유용성 평가
- A형 간염의 자연항체와 예방접종을 통한 항체 생성률의 역가 비교분석
- PET/CT 검사 시 체중과 체표면적에 따른 SUV의 상관관계
- PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가
- PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구
- UBC 검사의 이상결과에 대한 연구
- 동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교
- 상ㆍ하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰
- 융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발
- 방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰
- SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가
- PET/CT 검사에서 환자체형에 따른 적정검사 프로토콜에 관한 고찰
- Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구
- SPECT/CT에서 CT감쇠보정에 따른 영상의 질 평가
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 무증상 치밀 유방 여성에서 인공지능 기반 컴퓨터 보조 진단 장치의 유용성 연구
- 방사선치료 임상실습 환경에 따른 방사선(학)과 학생의 학습 효과 분석
- 딥러닝을 활용한 한국형 유방초음파 영상 정상-종괴 구분 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!