라식 수술 후 압평안압계와 비접촉성 안압계 측정치간 큰 차이를 보인 1예

이용수  0

영문명
A Wide Discrepancy between Intraocular Pressure by Applanation and Non-contact Tonometry after LASIK
발행기관
대한안과학회
저자명
김진철 정태영 기창원,Jin Chul Kim, M.D., Tae Young Chung, M.D., Chang Won Kee, M.D.
간행물 정보
『대한안과학회지』Ophthalmological Society,volume48,number6, 873~877쪽, 전체 5쪽
주제분류
인문학 > 역사학
파일형태
PDF
발행일자
2007.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To report the case of a glaucoma patient with a history of LASIK surgery who presented with a wide discrepancy in intraocular pressure between the Goldmann applanation tonometry and non-contact tonometry. Methods: A 20-year-old male glaucoma patient was referred to our clinic with a chief complaint of blurred vision in his right eye. The patient had a history of uneventful bilateral LASIK surgery. Upon our initial examination, his best-corrected visual acuity in the right eye was 0.04 and his right eye IOP was 14 mmHg by Goldmann applanation tonometry and 40 mmHg by non-contact tonometry. A slit lamp examination showed corneal epithelial edema with diffuse interface opacities. The central corneal thickness in the right eye was 587 ?m. An ultrabiomicroscopy demonstrated an interface fluid accumulation between the LASIK flap and the stromal bed. The patient was diagnosed with juvenile open-angle glaucoma and was scheduled for a trabeculectomy. Results: Seven days after trabeculectomy, the patient`s vision in the right eye improved to 0.7 and his IOP was 12 mmHg by Goldmann applanation tonometry and 14 mmHg by non-contact tonometry. In addition, the corneal epithelial edema, interface opacities, and fluids had all resolved and the central corneal thickness was reduced to 489 ?m. Conclusions: In eyes that have undergone LASIK surgery, the IOP measured by Goldmann applanation tonometry may underestimate the true pressure due to fluid accumulation under the LASIK flap. In such cases, non-contact tonometry can be a convenient and a reliable method for determining treatment plan.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김진철,정태영,기창원,Jin Chul Kim, M.D., Tae Young Chung, M.D., Chang Won Kee, M.D.. (2007).라식 수술 후 압평안압계와 비접촉성 안압계 측정치간 큰 차이를 보인 1예. 대한안과학회지, 48 (6), 873-877

MLA

김진철,정태영,기창원,Jin Chul Kim, M.D., Tae Young Chung, M.D., Chang Won Kee, M.D.. "라식 수술 후 압평안압계와 비접촉성 안압계 측정치간 큰 차이를 보인 1예." 대한안과학회지, 48.6(2007): 873-877

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제