본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia

이용수  3

영문명
발행기관
대한방사선종양학회
저자명
Hojin Kim Sangjoon Park Jihun Kim Jin Sung Kim Dong Wook Kim Nalee Kim Jae-Sun Uhm Daehoon Kim Hui-Nam Pak Chae-Seon Hong Hong In Yoon
간행물 정보
『대한방사선종양학회지』제42권 제4호, 319~329쪽, 전체 11쪽
주제분류
의약학 > 종양학
파일형태
PDF
발행일자
2024.12.31
4,120

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Purpose: Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance. Materials and Methods: The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion. Results: The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location. Conclusion: The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.

영문 초록

목차

Introduction
Materials and Methods
Results
Discussion and Conclusion
Statement of Ethics
Conflict of Interest
Funding
Author Contributions
Data Availability Statement
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Hojin Kim,Sangjoon Park,Jihun Kim,Jin Sung Kim,Dong Wook Kim,Nalee Kim,Jae-Sun Uhm,Daehoon Kim,Hui-Nam Pak,Chae-Seon Hong,Hong In Yoon. (2024).Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia. 대한방사선종양학회지, 42 (4), 319-329

MLA

Hojin Kim,Sangjoon Park,Jihun Kim,Jin Sung Kim,Dong Wook Kim,Nalee Kim,Jae-Sun Uhm,Daehoon Kim,Hui-Nam Pak,Chae-Seon Hong,Hong In Yoon. "Reinforcing treatment and evaluation workflow of stereotactic ablative body radiotherapy for refractory ventricular tachycardia." 대한방사선종양학회지, 42.4(2024): 319-329

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제