- 영문명
- A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT
- 발행기관
- 대한핵의학기술학회
- 저자명
- 이승재(Seung Jae Lee) 박훈희(Hoon-Hee Park) 안샤론(Sharon Ahn) 오신현(Shin Hyun Oh) 남궁혁(Heuk Nam-Koong) 임한상(Han Sang Lim) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee)
- 간행물 정보
- 『핵의학기술』Vol.12 No.2, 235~240쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2008.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis’ show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of ¹⁸F-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.
목차
서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES
해당간행물 수록 논문
- PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교
- Hospital Radiation Safety and Radioactive Waste Management (Radiation Protection in Nuclear Medicine - What’s our role ? -)
- 게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰
- 병원 내 방사선 작업종사자의 만성적 방사선 피폭에 의한 혈액학적 성분 변화에 관한 연구
- 역할 모델(Role model)을 이용한 업무 개선
- ¹⁸F-FDG PET/CT검사에서 지연영상을 이용한 갑상선 우연종 감별의 유용성 평가
- 고용량 방사성옥소 치료의 기본 Protocol 비교
- Article 고정상 추출법을 이용한 효율적인 [¹¹C]methionine의 합성
- SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가
- PET/CT에서 소아환자 영상 재구성 시 DFOV 변화의 유용성
- 이차성 고혈압 환자에서 알도스테론/혈장 레닌활성도 비율을 이용한 원발성 알도스테론증의 진단 및 임상적 유용성 평가
- 간담도 스캔 시 담즙 누출(Biliary Leakage)환자에서의 양측와위 자세(Both Decubitus Position)의 유용성
- 게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가
- 감마카메라의 Sensitivity 보정 Factor에 관한 연구
- 간질 PET영상을 위한 플루마제닐(벤조디아제핀 수용체)유도체의 신속하고 간단한 합성방법 소개
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
의약학 > 방사선과학분야 NEW
- 무증상 치밀 유방 여성에서 인공지능 기반 컴퓨터 보조 진단 장치의 유용성 연구
- Cardiofocal Collimator를 이용한 SPECT 검사 활용 증대 방안에 대한 연구: Brain SPECT를 중심으로
- 심장초음파의 좌심실이완기능장애와 대사증후군의 상관관계 분석
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!