- 영문명
- An Elimination of False-Positive I-131 Sites in Esophagus for Thyroid Carcinoma; Using Water with Vitamin C Dissolved
- 발행기관
- 대한핵의학기술학회
- 저자명
- 이승재(Seung Jae Lee) 박훈희(Hoon-Hee Park) 안샤론(Saron Ahn) 조석원(Seok won Cho) 최영숙(Young Sook Choi) 조응혁(Arther Cho) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee)
- 간행물 정보
- 『핵의학기술』Vol.12 No.1, 49~56쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2008.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose: Whole body imaging with radioiodine can detect functioning metastases. Non-physiologic I-131 uptake detected on images usually is interpreted as suggesting functioning thyroid metastases. However, extra-thyroidal I-131 accumulation does not always imply thyroid cancer metastases and has been reported in many circumstances. In order to avoid unnecessary therapeutic interventions it is important to distinguish false-positive sites of I-131 localization. We study here to remove false-positive sites around esophagus region on I-131 whole body imaging in patients who were administrated thyroidectomy. Materials and Methods: From April to August in 2007, we had the patients who had visited our department after they received thyroidectomy due to thyroid cancer. They were given I-131, and performed radioiodine body scan after 41 to 50 hours. Patients were whole-body-scanned for the speed of 8 cm per minute. After that, we took anterior and posterior static images around the patients’ neck measured by 300 thousand counts per image. We selected 44 patients who had hot spots around neck region, we divided the patients into two groups. One group was given 0.5 L of water and the other group was given 0.5 L of water with 1 g of Vitamin C dissolved. The patients were asked to drink the fluid for one minute in sitting position and after that, we measured 300 kilo counts per image again. We compared prior anterior, posterior static images with anterior, posterior images after the patients had water or water that Vitamin C resolved. Results: In using water, both observer 1 and 2 interpreted 6 patients were washed out. In the water with Vitamin C resolved, observer 1 and 2 interpreted 9 and 8 patients were washed out. Observer 1 and 2 interpreted 6 and 5 patients had ‘indeterminate’ when they used water. Both observer 1 and 2 interpreted 6 patients had ‘indeterminate’ when they used water with Vitamin C resolved. When they used water, observer 1 interpreted 10 patients had ‘unchanged’ and observer 2 interpreted 11 patients had ‘unchanged’. Differently, when they used water with vitamin C resolved, observer1 had 8 patients having ‘unchanged’and observer 2 had 9. Conclusion: As a result, by making patients drink 0.5 liter of water which has vitamin C resolved helped getting rid of false-positive sites in esophagus. Therefore, based on this study, we believe that drinking water with vitamin C dissolved is very in terms of reducing false-positive hot spot around the esophagus for the iodine-131 whole body scan.
목차
서론
대상 및 방법
결과
결론
고찰
요약
INTRODUCTION
MATERIALS AND METHODS
RESULTS
CONCLUSION
DISCUSSION
REFERENCES
해당간행물 수록 논문
- RI사용 의료기관의 효율적인 배기관리 방안
- 갑상선암의 고용량 방사성옥소 치료교육
- 방사성옥소 치료를 위한 표준 지침서 개발과 치료병실 환경 개선 연구
- 두경부 혈관종 진단시 99mTc-RBC Scan and SPECT 검사의 유용성
- 용혈이 Vitamin B12 / Folic acid 검사 결과에 미치는 영향
- Adiponectin Reference Range설정과 임상적 의의 고찰
- 방사성옥소 치료환자의 환의 및 침구류에 대한
- The Importance of Filter Integrity Test to Ensure Sterility of Radiophamaceuticals for Using PET Image
- ¹⁸F-FDG PET 검사를 위한 당뇨 환자의 혈당 조절에 관한 연구
- 유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가
- CA 19-9 검체량에 따른 농도의 변화
- Onco. Flash Processing 적용에 따른 핵의학 영상의 유용성 평가
- 치료병실에서 배출되는 방사성오염 폐기물의 처리 방안
- 고용량 방사성옥소 치료병실의 오⋅폐수 저감화를 위한 연구
- 동위원소 치료병실의 I-131 배출에 대한 小考
- Barium 조영제의 농도 차이가 PET 검사에 미치는 영향
- 방사면역측정키트 성능평가 고찰
- 방사성옥소 치료를 받는 갑상선암 환자의 만족도 개선 연구
- Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구
- 갑상선암의 방사성옥소 치료 후 전신 스캔에서 비타민C 용액을 이용한 식도의 위양성 병소 제거에 대한 고찰
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
의약학 > 방사선과학분야 NEW
- 무증상 치밀 유방 여성에서 인공지능 기반 컴퓨터 보조 진단 장치의 유용성 연구
- Cardiofocal Collimator를 이용한 SPECT 검사 활용 증대 방안에 대한 연구: Brain SPECT를 중심으로
- 심장초음파의 좌심실이완기능장애와 대사증후군의 상관관계 분석
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
