초음파 검사용 젤과 젤 용기의 세균증식 원인
이용수 18
- 영문명
- Causes of Bacterial Growth in Gels and Gel Containers Used for Ultrasonography
- 발행기관
- 대한방사선과학회(구 대한방사선기술학회)
- 저자명
- 김아영(A-Young Kim) 조평곤(Pyoung-Kon Cho) 송도영(Do-Young Song) 김수정(Su-Jung Kim)
- 간행물 정보
- 『방사선기술과학』방사선기술과학 제43권 제5호, 359~365쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2020.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
This study aimed to investigate the causes of bacterial growth to prevent infection caused by ultrasound gel and gel containers in contact with patients during ultrasonography. To investigate bacterial contamination during manufacturing or storage, we cultured ultrasound gels originally supplied from three manufacturers. To analyze bacterial growth according to the lapse of time and frequency of use of the ultrasound gel container, the gel and container were cultured at regular intervals every week for 4 weeks. In addition, to determine the source of infection, the examiner s hand was inspected with hand plate and the degree of bacterial contamination was measured before the test. As a result of the study, bacteria were not detected in the gel provided at the initial supply, and in the gel and gel container used repeatedly for 4 weeks, the same bacteria residing on the skin were identified in the examiner s hand, such as Staphylococcus epidermidis, Micrococcus luteus, Leuconostoc mesenteroid spp cremoris, Kocuria rhizophila, and etc. Separated strains were classified as those of the low- or non-pathogenicity; however, most of these strains may render fatal consequences to patients of lower level of immunity due to acquired tolerance to antibiotics. At week 1, when the number of tests was the highest, 44 colonies were identified, and at week 4, when the number of tests was the lowest, 4 colonies were identified. As r=0.994, it was found that the number of colonies increased as the number of tests increased. In conclusion, it was confirmed that the cause of the infection was not the ultrasound gel, but the examiner s hand. The ultrasound gel or gel container may be contaminated by skin flora of examiner s hands, which can cause opportunistic infection in patients with low immunity. The ultrasound gel or gel container may be contaminated by skin flora of examiner s hands, which can cause opportunistic infection in patients with low immunity. Therefore, it was confirmed that thorough hand disinfection was necessary to block healthcare-associated infections.
목차
Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
REFERENCES
해당간행물 수록 논문
- 코로나바이러스 감염증19 데이터베이스에 기반을 둔 인공신경망 모델의 특성 평가
- 유방촬영 시 몬테칼로 전사모사를 이용한 유방 성형 환자의 장기선량 평가
- 초음파 검사용 젤과 젤 용기의 세균증식 원인
- 스티칭 기법을 이용한 대퇴골 방사선검사 시 확대 표식자 위치 및 스티칭 범위 변화가 영상에 미치는 영향
- PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정
- 초음파검사실 감염관리 인식에 대한 연구
- 고 에너지 양성자 가속기에서 생성되는 2차 방사선의 효과적인 차폐에 관한 연구
- 몬테칼로 시뮬레이션을 활용한 양성자가속기 단기사용 시 구성품의 방사화 평가
- 안와 전산화단층촬영검사 시 수정체 선량감소 방법과 영상 평가
- 인터벤션 방사선발생장치에서 입사표면선량률 평가
- 자동노출조절장치를 이용한 흉부 방사선검사 시 갑상샘 장기선량 최소화를 위한 새로운 차폐 방법에 관한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 무증상 치밀 유방 여성에서 인공지능 기반 컴퓨터 보조 진단 장치의 유용성 연구
- 방사선치료 임상실습 환경에 따른 방사선(학)과 학생의 학습 효과 분석
- 딥러닝을 활용한 한국형 유방초음파 영상 정상-종괴 구분 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!