본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구

이용수  27

영문명
Radiographic Study of Cobey Method and Modified Cobey Method
발행기관
대한방사선과학회(구 대한방사선기술학회)
저자명
고유림(Yu-Rim Go) 주영철(Young-Cheol Joo) 이승근(Seung-Keun Lee)
간행물 정보
『방사선기술과학』방사선기술과학 제42권 제3호, 167~173쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2019.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore, the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed. Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from 10° to 40° at 5° intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from 10° to 40° at intervals of 5° for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ㎳, and 110 ㎝ of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 ㎜ and the medial point is about 4.3㎜ longer than lateral malleolus. Also, when the X-ray tube angle is more than 20°, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the 20° detector angle of the Cobey. In addition, we suggest that tube angle should be limited within 20° when modified Cobey is performed.

목차

Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

고유림(Yu-Rim Go),주영철(Young-Cheol Joo),이승근(Seung-Keun Lee). (2019).Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구. 방사선기술과학, 42 (3), 167-173

MLA

고유림(Yu-Rim Go),주영철(Young-Cheol Joo),이승근(Seung-Keun Lee). "Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구." 방사선기술과학, 42.3(2019): 167-173

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제