학술논문
Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구
이용수 27
- 영문명
- Radiographic Study of Cobey Method and Modified Cobey Method
- 발행기관
- 대한방사선과학회(구 대한방사선기술학회)
- 저자명
- 고유림(Yu-Rim Go) 주영철(Young-Cheol Joo) 이승근(Seung-Keun Lee)
- 간행물 정보
- 『방사선기술과학』방사선기술과학 제42권 제3호, 167~173쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2019.06.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore,
the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed.
Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from 10° to 40° at 5° intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from 10° to 40° at intervals of 5° for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ㎳, and 110 ㎝ of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 ㎜ and the medial point is about 4.3㎜ longer than lateral malleolus. Also, when the X-ray tube angle is more than 20°, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the 20° detector angle of the Cobey. In addition, we suggest that tube angle should be limited within 20° when modified Cobey is performed.
목차
Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
해당간행물 수록 논문
- Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구
- 복부 초음파검사에서 영상 점수 시스템 분류에 따른 간 섬유화 평가의 유용성
- 동맥천자 인터벤션 시술 후 지속지혈 안전성에 대한 연구
- 체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가
- 간동맥 화학색전술 후 풍선형 지혈기구의 유용성
- 방사선기술과학 제42권 제3호 목차
- 3D 프린팅을 이용한 한국인 골밀도 맞춤 팬텀 개발
- 방사선사 조직의 조직유효성에 영향을 미치는 변수에 관한 연구
- 핵의학과 PET/CT실 방사선작업종사자의 수정체 부위의 등가선량과 흉부의 유효선량의 측정 비교
- 디지털유방촬영에서 Geant4-GATE를 이용한 산란선의 영향분석과 감소방안에 관한 연구
- 방사선기술과학 제42권 제3호 안내
- 갑상선 결절 유병률과 초음파 영상에서 악성소견 결절의 형태학적 분석
- 「방사선기술과학」 투고규정
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 고준위방사성폐기물 관리와 관련된 사회안전망 구축에 관한 연구
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 무증상 치밀 유방 여성에서 인공지능 기반 컴퓨터 보조 진단 장치의 유용성 연구
- 방사선치료 임상실습 환경에 따른 방사선(학)과 학생의 학습 효과 분석
- 딥러닝을 활용한 한국형 유방초음파 영상 정상-종괴 구분 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!