본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Comparison of Surgically Induced Astigmatisms after Clear Corneal Incisions of Different Sizes

이용수  0

영문명
발행기관
대한안과학회
저자명
Sung Chur Moon Tarek Mohamed I. Howard Fine
간행물 정보
『The Korean Journal of Ophthalmology』Vol.21 No.1, 1~5쪽, 전체 5쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2007.03.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: This study was performed to assess efficiency and stability of astigmatic change by incision size after cataract surgery. Methods: This work was designed as a retrospective, comparative, nonrandomized interventional study. A total of 121 cases of cataract surgery were reviewed in 98 patients performed by one surgeon at the Oregon Eye Institute in Eugene, OR, USA with 3-year follow-ups. All procedures were performed with the temporal approach of self-sealing incisions. The serial change in surgically induced astigmatisms were examined in all cases of three groups: Group A, cartridge injection of a foldable IOL through a 2.5 mm self-sealing incision; Group B, cartridge injection of a foldable IOL through a 3.0 mm self-sealing incision; Group C, cartridge injection of a foldable IOL through a 3.5 mm self-sealing incision. Keratometric data were obtained preoperatively, and 3 weeks, 3 months, 6 months, 9 months, 12 months, 24 months and 36 months postoperatively. Polar value analysis was performed to calculate the surgically induced astigmatism. Results: The astigmatic change decreased over time in Group B (P<0.05). The other groups tended to remain in induced astigmatism. All groups showed anticlockwise torque at 3 weeks following surgery. Group B showed a decrease in deviation, but the other groups showed increases in their torque value at postoperative 12 months (P<0.05). Conclusions: The 3.0 mm incision size correlated with the least surgically induced astigmatism.

목차

Materials and Methods
Results
Discussion
Acknowledgements
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Sung Chur Moon,Tarek Mohamed,I. Howard Fine. (2007).Comparison of Surgically Induced Astigmatisms after Clear Corneal Incisions of Different Sizes. The Korean Journal of Ophthalmology, 21 (1), 1-5

MLA

Sung Chur Moon,Tarek Mohamed,I. Howard Fine. "Comparison of Surgically Induced Astigmatisms after Clear Corneal Incisions of Different Sizes." The Korean Journal of Ophthalmology, 21.1(2007): 1-5

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제