본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Predictability for proper capsular tension ring size and intraocular lens size

이용수  0

영문명
발행기관
대한안과학회
저자명
Eun Young Dong Choun Ki Joo
간행물 정보
『The Korean Journal of Ophthalmology』Vol.15 No.1, 22~26쪽, 전체 5쪽
주제분류
인문학 > 역사학
파일형태
PDF
발행일자
2001.06.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Predicting correct capsular tension ring size and intraocular lens size using measurements of lens diameter, corneal diameter, axial length and capsular bag diameters to determine anatomical relationships of post implantation capsular tension ring (CTR). The vertical and horizontal diameters of cornea and lens were measured in 62 human eyeballs supplied from the eye bank of the Catholic University. The relationship between corneal diameter and axial length was examined in 195 living human eyes. An extension of capsular bag diameter after implantation of CTR was measured in 19 pigs’ eyes purchased from a slaughter house. The correlation between the lens diameter and the capsular bag diameter after CTR implantation was analyzed using linear regression. The average diameters (mean of horizontal and vertical diameters) of cornea and lens in human eyeball of postmortems (average age:69, ratio of male:female = 23:39) were 11.59±0.42 mm for horizontal diameter, 9.54±0.27 mm, for vertical diameter. The average corneal diameters and axial lengths in living human eyes (average age: 62, ration of male:female = 84:111) were 11.63±0.53 mm for the cornea diameter, 24.48±2.10 mm, for cornea axial length. There is a statistically significant correlation between corneal diameter and axial length (correlation coefficient=0.788; p<0.001) and corneal diameter and lens diameter (correlation coefficient=0.711; p<0.001). In pigs’ eyes, there is a relationship between lens diameter and capsular bag diameter after implantation of 11 mm CTR (correlation coefficient=0.684; p<0.001). In conclusion, axial length and corneal diameter may give surgeons a valuable clue to expected size of capsular bag and important parameters for selecting the correct sized CTR and IOL.

목차

Abstract
INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Eun Young Dong,Choun Ki Joo. (2001).Predictability for proper capsular tension ring size and intraocular lens size. The Korean Journal of Ophthalmology, 15 (1), 22-26

MLA

Eun Young Dong,Choun Ki Joo. "Predictability for proper capsular tension ring size and intraocular lens size." The Korean Journal of Ophthalmology, 15.1(2001): 22-26

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제