- 영문명
- Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings
- 발행기관
- 한국환경보건학회
- 저자명
- 김윤신 이은규 엽무종 김기영
- 간행물 정보
- 『한국환경보건학회지』제28권 제1호, 85~92쪽, 전체 8쪽
- 주제분류
- 공학 > 환경공학
- 파일형태
- 발행일자
- 2002.03.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991 - February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001 - June 2001 in Seoul. Sites including book store, department store, theater, subway station, underground shopping center, hospital, office building, sports facility, and eduationa institutio were chosen to measure indoor microorganism. The results were as follows: 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. The highest concentration of 711cfu/m3 was found in the subway station and the lowest concentration of 44cfu/m3 was found in office building. 2. The average of staphylococci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. The highest concentration of 502cfu/m3 was found in the subway station and the lowest concentration of 14cfu/m3 was found in sports facility and educational institution. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites. The highest concentration of 252cfu/m3 was found in the hospital and the lowest concentration of 32cfu/m3 was found in office building. 4. Ratio of Indoor/Outdoor, determined by site was 1.12-2.38 in total count, 1.00-2.35 in staphylococci, and 0.99-1.34 in fungus. 5. The positive results of test were 12-24% in indoor and 9-43% in outdoor. 6. By gram staining gram positive cocci were 59.9%, gram positive bacill 24.4%, gram negative bacilli 10.4%, and gram negative cocci 0.5%.
목차
해당간행물 수록 논문
- 지리정보시스템을 이용한 소유역의 환경정보체계 구축
- 국내 중앙 일간지 환경보도의 정확성에 관한 연구
- PC방에서의 간접흡연에 따른 요중 코티닌의 농도
- 흰쥐를 이용한 IBP의 경구투여 및 피부도포 후 요중 대사물질 측정
- 고정화 미생물 반응조의 운전특성 및 생활하수처리 적용
- 현장 도금 공정에서 PVC 여과지에 채취된 6가 크롬의 환원
- 다중이용시설에서의 실내공기중 미생물 분포에 관한 연구
- 디클로로벤지딘에 폭로된 흰쥐의 간장세포와 방광 상피세포에 형성된 DNA adducts의 32 P-postlabeling과 GC/MS-SIM에 의한 분석
- 소규모 쓰레기 매립장 침출수의 효율적인 처리 방안에 관한 연구
- 슬러지 탄소원을 주입한 UNR공정의 동절기 질소, 인 처리효율
참고문헌
관련논문
공학 > 환경공학분야 BEST
- 대구 달성군 산업단지 휘발성유기화합물 건강위해평가 및 배출원 추적
- 우리나라 청소년의 혈청 중 과불화화합물과 아토피 피부염 간의 연관성: 제4기 국민환경보건 기초조사(2018~2020)
- 주요 선진국과 한국의 실내공기질 기준에 따른 비교 분석: 환경보건학적 관점에서
공학 > 환경공학분야 NEW
더보기최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!