Evaluation of Water Suction for Compacted Bentonite Buffer Under Elevated Temperature Conditions
이용수 0
- 영문명
- 발행기관
- 한국방사성폐기물학회
- 저자명
- Seok Yoon Deuk-Hwan Lee Won-Jin Cho Changsoo Lee Dong-Keun Cho
- 간행물 정보
- 『Journal of Nuclear Fuel Cycle and Waste Technology (JNFCWT)』Vol.20 No.2, 185~192쪽, 전체 8쪽
- 주제분류
- 공학 > 공학일반
- 파일형태
- 발행일자
- 2022.06.30

국문 초록
A compacted bentonite buffer is a major component of engineered barrier systems, which are designed for the disposal of high-level radioactive waste. In most countries, the target temperature required to maintain safe functioning is below 100°C. If the target temperature of the compacted bentonite buffer can be increased above 100°C, the disposal area can be dramatically reduced. To increase the target temperature of the buffer, it is necessary to investigate its properties at temperatures above 100°C. Although some studies have investigated thermal-hydraulic properties above 100°C, few have evaluated the water suction of compacted bentonite. This study addresses that knowledge gap by evaluating the water suction variation for compacted Korean bentonite in the 25–150°C range, with initial saturations of 0 and 0.22 under constant saturation conditions. We found that water suction decreased by 5–20% for a temperature increase of 100–150°C.