Background: There is no evaluation or management of environmental low-frequency noise and there are few
studies on it, particularly in the area surrounding thermal power plants.
Objectives: This study aimed to conduct continuous measurement of low-frequency noise for 24 hours
and cross-measurement from the thermal power plant site boundary line in order to understand the spatial
distribution characteristics of low-frequency noise and evaluate it based on the low-frequency noise sound
pressure level.
Methods: The low-frequency noise measurement was checked for excess in each frequency band by time at
four sites over three consecutive times for 24 hours. Cross-measurements were made for 30 minutes at each
of five sites by separation distance from the site boundary line of the thermal power plant. The measurement
method was traced to the frequency exceeding nine octave bands (12.5 Hz to 80 Hz) according to the “Low
Frequency Noise Guidelines” proposed by the Ministry of Environment. The Z characteristic (dB(Z)) was
applied as well.
Results: As a result of the 24-hour continuous measurement, the sound pressure level for each frequency
tended to decrease as the separation distance increased. As a result of cross-measurement, in the case of 80 Hz
and 63 Hz, all five points exceeded the sound pressure level standard of the Ministry of Environment. In the
case of 56 Hz and 40 Hz, the sound pressure level standard was exceeded at the thermal power plant boundary
line and thermal power plant boundary line separation distance of 310 m.
Conclusions: In the area surrounding a low-frequency noise source, four frequencies (80 Hz, 63 Hz, 50 Hz,
and 40 Hz) were found to have affected the residential area adjacent to the power plant. This study suggests a
need for continuous monitoring of residential areas near thermal power plants for low-frequency noise and
the establishment of environmental guidelines.
영문 초록
목차
I. 서 론
II. 재료 및 방법
III. 결 과
IV. 고 찰
감사의 글
Conflict of Interest
References
해당간행물 수록 논문
참고문헌
- Statistics of electric power in Korea 2022
- Ind J Occup Environ Med
- J Low Freq Noise Vib Act Control
- Noise Health
- J Low Freq Noise Vib Act Control
- J Sound Vib
- Appl Acoust
- Occup Environ Med
- J Acoust Soc Am
- Noise Health
- Noise Control Eng J
- J Low Freq Noise Vib Act Control
- J EIA
- Sci Rep
- Environ Forum
- J Acoust Soc Korea
- Noise Health
- Department for Environment, Food & Rural Affairs
- Encyclopedia of environmental health
- Noise Health
- J Acoust Soc Am
- J Sound Vib
- Sci Total Environ
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!