영문 초록

Purpose: There are 3 warnings for Glucagon tests. First, EDTA tubes that already contain Aprotinin must be used for plasma collection. Second, for freezer storage of centrifuged plasma, glass tubes must be used. Last, glass tubes must be used for testing procedure. So we compared the glucagon results of next 3 situation to those of control group. First, We compared to results by tubes without Aprotinin and with aprotinin. Second, we compared to results by tubes(plastic vs glass) for plasma storage. Third, we compared to results by tubes(plastic vs glass) for testing. We tried to evaluate the results of the 3 different condition. Materials and Methods: 40 healthy adults were studied with normal results on the general medical check up and laboratory tests. We compared the results of 3 different condition belows: Blood were collected in EDTA tube containing aprotinin and plasma was stored in the glass tube for 3 days in a freezer and results were obtained by tests in the glass tubes. Results from EDTA plasma without aprotinin, results from platic tubes for freezer stroage, results from plastic tube when testing. Simple linear regression analysis and paired t-test using SPSS were done for statistical analysis. Commercial glucagon kit(RIA-method)which made by Siemens company were used. Results: Correlation coefficient between results of EDTA tubes with Aprotinin vs without Aprotinin was r = 0.783 (p = 0.064). Result of specimen in plastic tubes stored 3 days in a freezer showed lower value compared to those in glass tube(r = 0.979, p = 0.005). Also, results of testing in plastic tubes showed lower values than those testing in glass tubes. (r = 0.754, p <0.001). Conclusion: It is recommended for glucagon determination to use EDTA tube with Aprotinin which is a inhibitor of protein breakdown enzyme. Results of plastic tube when storage and testing showed lower value than those of glass tubes, so it is recommended to store and test in glass tubes.

목차

서론
실험재료 및 방법
결과
결론 및 고찰
요약
RFEFRENES

키워드

해당간행물 수록 논문

참고문헌

최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

조윤교(Youn Kyo Cho),최삼규(Sam Kyu Choi),서소연(So Yeon Seo),신용환(Yong Hwan Shin). (2011).Glucagon 검사시 Aprotinin 첨가와 Plastic tube 사용이 미치는 영향. 핵의학기술, 15 (1), 117-120

MLA

조윤교(Youn Kyo Cho),최삼규(Sam Kyu Choi),서소연(So Yeon Seo),신용환(Yong Hwan Shin). "Glucagon 검사시 Aprotinin 첨가와 Plastic tube 사용이 미치는 영향." 핵의학기술, 15.1(2011): 117-120

sam 이용권 선택
님이 보유하신 이용권입니다.
차감하실 sam이용권을 선택하세요.