- The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media
- 발행기관
- 대한핵의학기술학회
- 저자명
- 안샤론(Sharon Ahn) 박훈희(Hoon Hee Park) 박민수(Min Soo Park) 오신현(Shin Hyun Oh) 이승재(Seung Jae Lee) 임한상(Han sang Lim) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee)
- 간행물 정보
- 『핵의학기술』Vol.13 No.1, 77~81쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2009.05.30
국문 초록
영문 초록
Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. ¹⁸F- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients’ weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.
목차
서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!