- 영문명
- Assessment of airborne bacteria and particulate matters distributed in Seoul metropolitan subway stations
- 발행기관
- 한국환경보건학회
- 저자명
- 김기연(Ki Youn Kim) 박재범(Jae Beom Park) 김치년(Chi Nyon Kim) 이경종(Kyung Jong Lee)
- 간행물 정보
- 『한국환경보건학회지』제32권 제4호, 254~261쪽, 전체 8쪽
- 주제분류
- 공학 > 환경공학
- 파일형태
- 발행일자
- 2006.08.30
국문 초록
영문 초록
In activity areas of subway workers and passengers in Seoul metropolitan subway lines 1-4, mean concentrations of airborne bacteria were relatively higher in workers bedroom and station precinct whereas concentrations of particulate matters, PM10 and PM2.5, were relatively higher in platform, inside train and driver s seat as compared with other activity areas. This result indicates that little correlation between airborne bacteria and particulate matters was found, which assumed that most airborne particulate matters distributed in subway consisted of mainly inorganic dust like a metal particles. Mean concentrations of PM10 and PM2.5 in station precinct and platform exceeded the threshold limit value (PM10 : 150 g/m3, PM2.5 : 65 g/m3) but those in station office and ticket office were below it. The genera identified in all the activity areas of subway over 5% detection rate were Staphylococcus, Micrococcus, Bacillus and Corynebacterium, of which Staphylococcus and Micrococcus covered over 50% of total airborne bacteria and were considered as predominant genera distributed in subway.
목차
Ⅰ. 서론
Ⅱ. 실험방법
Ⅲ. 결과 및 고찰
Ⅳ. 결론
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!