- 영문명
- Effect of Municipal Sewage Treatment Plant on Water Quality in Western Kangwon Area
- 발행기관
- 한국환경보건학회
- 저자명
- 허인량(In-Ryang Huh) 최지용(Ji-Yong Choi) 김영진(Yeong-Jin Kim) 정의호(Ui-Ho Jeong)
- 간행물 정보
- 『한국환경보건학회지』제31권 제4호, 235~240쪽, 전체 6쪽
- 주제분류
- 공학 > 환경공학
- 파일형태
- 발행일자
- 2005.08.30

국문 초록
영문 초록
The effects of municipal sewage treatment plants on the water quality and effluent loading were investigated. BOD removal rates from Wonju, Hoengseong, and Hongcheon municipal sewage treatment plants were 88.9%, 80.6%, 90.7% and T-P removal rates were 47.3%, 56.5%, 71.6%, respectively. Also, BOD effluent loading from WonJu, Hoengseong, and Hongcheon treatment plants were 1,520 kg/day, 75 kg/day, 55 kg/day and T-P effluent loading were 203.9 kg/day, 4.2 kg/day, 4.0 kg/day, respectively. In terms of water quality distribution by distance of flow, BOD of the Seom river rapidly rose from 1.6mg/l to 4.0mg/l and T-P rose from 0.034mg/l to 0.321mg/l. Also BOD of the Hongcheon river showed a slowly rise from 1.1mg/l to 1.4mg/l and T-P from 0.011mg/l to 0.026mg/l. In conclusion, the effects of municipal sewage treatment plants on the water quality proved that T-P was higher than BOD. Consequently, in order to improve water quality, it is necessary to adopt an advanced sewage treatment system like nutrient removal.