- 영문명
- An Experimental Study on the Fire Resistance effect on load ratio and compressive strength of the CFT Column under loading in fire
- 발행기관
- 한국화재소방학회
- 저자명
- 조경숙(Cho, Kyung-Suk) 김흥열(Kim, Heung-Youl) 김형준(Kim, Hyung-Jun) 권인규(Kwon, In-Kyu) 박경훈(Park, Kyung-Hun)
- 간행물 정보
- 『한국화재소방학회 학술대회논문집』2010년도 춘계학술논문발표회 논문집, 371~376쪽, 전체 6쪽
- 주제분류
- 공학 > 공학일반
- 파일형태
- 발행일자
- 2010.04.30

국문 초록
영문 초록
The strength of steel material in a concrete filled steel tube (CFT) is reduced in fire, but the filled interior concrete structurally ensures the fire resistance due to its high thermal capacity. More, the contractibility of CFT is excellent since it can be constructed without form work. This research analyzed the interior concrete strength and deformation characteristics, which are the influence factors of the fire resistance of CFT, in proportion to the axial load ratio. The fire resistance performance according to changes of the axial load ratio showed great fluctuation. As $280{\times}280{\times}6$ CFT columns with the concrete strengths of 24 MPa and 40 MPa and the axial load ratios of 0.9, 0.6, and 0.2 in accordance with KS F 2257-1 and 7 were heated with loading to examine the fire resistance performance, the 24 MPa concrete exhibited the fire resistance time as 27, 113, and 180 minutes for the axial load ratios, 0.9, 0.6, and 0.2 respectively. In case of 40 MPa concrete, the fire resistance time were turned out to be 19 and 28 minutes for the axial load ratios, 0.9 and 0.6 respectively. The results of 40 MPa concrete showed the much lower fire resistance performance when comparing with those of 24 MPa concrete. The fire resistance performance was not increased significantly when the axial load ratio was reduced. Therefore, the deceased fire resistance performance of high strength concrete is assumed to be caused by the internal pressure increase upon the heat application.
목차
키워드
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!