- 영문명
- Comparison of the Equivalent Dose of the Lens Part and the Effective Dose of the Chest in the PET/CT Radiation Workers in the Nuclear Medicine Department
- 발행기관
- 대한방사선과학회(구 대한방사선기술학회)
- 저자명
- 손상준(Son Sang-Joon) 박정규(Park Jeong-Kyu) 정동경(Jung Dong-Kyung) 박명환(Park Myeong-Hwan)
- 간행물 정보
- 『방사선기술과학』방사선기술과학 제42권 제3호, 209~215쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2019.06.30

국문 초록
영문 초록
Comparison of the effective dose of the chest and the equivalent dose of the lens site in the radiation workers
working at four medical institutions with the PET / CT room located in one metropolitan city and province from April 1
to June 30, 2018 Respectively. Radioactive medicine were measured at the time of dispensing and at the time of
injection. In this experiment, the average dispensing time per patient was 5.7 minutes and the average injection time was 3.1 minutes. The equivalent dose at the lens site was 0.78 μSv/h for 1 mCi, and the effective dose for chest was 0.18 μ Sv/h per 1 mCi. The equivalent dose at the lens site during injection was 0.88 μSv/h per mCi and the effective dose of chest was 0.20 μSv/h per mCi. The daily effective dose of the chest was 0.9±0.6 μSv and the equivalent dose of the lens site was 3.6±1.4 μSv during daily dosing for 20 days. The effective dose of the chest during the day was 0.6±0.5 μSv and the equivalent dose of the lens was 2.2±1.0 μSv. At the time of dispensing, the equivalent dose of the lens was 0.187±0.035 mSv, the effective dose of the chest was 0.137±0.055 mSv, the equivalent dose of the lens was 0.247±0.057 mSv, and the effective dose of the monthly chest was 0.187±0.021 mSv. As a result of the corresponding sample test, the equivalent dose and the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, The equivalent dose of the lens and the effective dose of the chest were statistically significant (p<0.05) with a significance of 0.000. However, there was no statistically significant difference (p>0.05) between the equivalent dose and the effective dose of the chest, the equivalent dose of the lens at the time of injection, and the effective dose of the chest at 0.138 and 0.230, respectively.
목차
Ⅰ. 서 론
Ⅱ. 대상 및 방법
Ⅲ. 결 과
Ⅳ. 고 찰
Ⅴ. 결 론
키워드
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!