학술논문
Cardiac CT에서 Dual injector의 Dual flow technique을 이용한 Contrast media의 Optimize admix rate에 관한 연구
이용수 0
- 영문명
- Assessment of optimize admix rate in dual flow technique by dual injector : non invasive 64 row multi detector CT
- 발행기관
- 대한CT영상기술학회
- 저자명
- 배경덕(Kyoung Deok Bae) 김상현(Sang Hyeon Kim) 성열훈(Yeul Hoon Sung) 대창민(Chang Min Dae) 민관홍(Kaen Hong Min) 김성룡(Seong Roung Kim)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제10권 제1호, 153~157쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2008.04.30

국문 초록
영문 초록
Purpose
When examining cardiac CT, in Dual flow technique which is using for Right atrium and ventricle’s correct increase and Strike artifact decrease, after injection of 1st phage which has genuine contrast media, when injecting 2nd phage which is mixed contrast media with saline solution, we are to search for optimize admix rate.
Materials and Methods
We examined CT coronary angiography to 120 persons (comparative group n=20, experimental group n=100) who took a health inspection from 4th of July to 25th of July in this hospital.
When examining, we injected only saline solution to comparative group (n=20) in 2nd phage, experimental group (n=100) was divided into I ~ V groups, 20 persons each, and using Dual flow technique, we injected the mixed contrast media with saline solution to each group with different rate 1:9, 2:8, 3:7, 4:6, 5:5.
All data of comparative group and experimental group measured Hounsfield Unit of RA(Right Atrium), RV(Right Ventricle), LA(Left Atrium), LV(Left Ventricle), RCA(Right Coronary Artery), MS(Myocardium Septum) by Workstation.
2 of the department of diagnostic radiology specialist and 2 of the department of radiology technologist compared and analyzed the images of each group with a faithful evaluation.
Results
Comparing the average HU of LA, LV, MS, RCA in all of the comparative group and the experimental group, there’s no difference.
But at RA and RV, the average HU of the experimental group was higher than the comparative group’s, we could know that the more the mixed contrast media, the greater the difference remarkably. and, in an image evaluation, it effected more to diagnose the experimental group’s RV structure than the comparative group’s. especially it showed the excellence in III group.
Conclusion
Dual flow technique was a more valid method than Saline chaser technique regarding demand of Strike artifact of Right atrium and functional rating and fabric diagnosis of Right atrium. About the present experiment, the group of 3 : 7 which is the rate of contrast medium and saline among Dual flow technique. But it would be considered that the rate would change gradually according to Iodine content of contrast medium.
목차
Abstract
I. 서론
II. 대상 및 방법
III. 결과
IV. 고찰
V. 결론
참고문헌
키워드
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
