- 영문명
- Difference of Radiation Exposure in Computed Tomography (CT) by Anthropometric Characteristics and the Methods of Exposμre
- 발행기관
- 대한CT영상기술학회
- 저자명
- 왕태욱(Tae Uk Wang) 박재훈(Jae Hoon Park) 방순욱(Soon Uk Bang) 범희남(Hyi Nam Bum) 임채평(Chae Pyeong Lim)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제9권 제1호, 63~72쪽, 전체 10쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2007.04.30

국문 초록
영문 초록
Purpose
To minimize the radiation exposure during the computed tomography (CT) examination, the practical amount of radiation exposure was reviewed in terms of anthropometric characteristics of the examinees and the methods of exposure control - automatic and manual.
Materials and Methods
During 5 months from March to July 2006, radiation exposure data of 200 examinees who had either chest or abdominal CT examination were collected from 16 channel slice multidetector row CT (16 slice MDCT, equipment A) and 64 channel slice multidetector row CT (64 slice MDCT, equipment B) in Hwasun Chonnam national University Hospital. Data were analyzed in relation to examinee’s body mass index (BMI), age, sex and noise index. The difference of radiation exposure between automatic and manual exposure control were also analyzed respectively
Results
Of total 400 examinees (267 men and 133 women), the amount of radiation exposure was significantly correlated with BMI, body weight and the noise index. The noise index was positively related with body weight.
In both equipments, the automatic exposure generally showed lower radiation exposure than manual exposure. The radiation exposure in abdominal examination in e quipment A, however, showed higher radiation exposure in the automatic exposure than in the manual exposure, although statistically insignificant. The exposure levels were higher in the automatic exposure in the 82 percent of abdominal examinees for the equipment A.
Conclusion
Generally speaking, the automatic exposure method are superior to the manual exposure method to minimize the amount of radiation exposure during the CT examination. But this is not always the case. This study suggest that all the exposure protocol for the CT examination be reviewed through practical evaluation at the actual settings.