학술논문
Cardiac Functional Analysis를 위한 ECG-gated MDCT의 유용성과 MRI, SPECT, Echocardiography와의 비교분석
이용수 5
- 영문명
- The Usefulness of ECG-gated MDCT for The Cardiac Functional Analysis; and Comparison with MRI, SPECT, Echocardiography
- 발행기관
- 대한CT영상기술학회
- 저자명
- 정한별(Han Byul Jeong) 김영옥(Young Ok Kim) 구본승(Bon Seung Goo) 대창민(Chang Min Dae) 민관홍(Gwan Hong Min) 김성룡(Seong Ryong Kim)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제8권 제1호, 127~136쪽, 전체 10쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2006.04.30

국문 초록
영문 초록
Purpose
In the evaluation of ischemic heart disease, accurate measurement of cardiac function is very important as well as the evaluation of vessel status of coronary artery. therefore we evaluate the accuracy of cardiac functional analysis using ECG-gated MDCT compare with other imaging modality such as MRI, single photon emission computed tomography and echocardiography.
Materials and Methods
We recruited 21 patients(age range:51~78, mean age:62.8±10.69, sex: male-13 female-8) with ischemic heart disease that underwent 4 exam(CT, MRI, single photon emission computed tomography and Echo) all within 1 month. We used 16 slice MDCT(Mx8000 IDT, Philips Medical Systems, Netherland) and dual injector(Medrad, USA). We measured 4 cardiac functional data(ejection- fraction %, end-diastolic volume, end-systolic volume and mass) of left ventricle. To measure data, we used end-systolic & end-diastolic reconstruction phase during cardiac cycle in ECG-gated cardiac CT. 4 cardiac functional data(EF, EDV, ESV and mass) were measured at short axis view using semiautomated contour technique in Extended Brilliance workstation(Brilliance version 2.0, Philips Medical Systems). This cardiac functional data obtained from CT was compared with MRI, ECG-gated single photon emission computed tomography, echocadiography. MRI is known to reference standard of cardiac function. therefore we analyzed the accuracy of cardiac functional data each modality(CT, single photon emission computed tomography, echocadiography) compared with MRIcardiac functional data as reference of standard.
Results
We analyze difference MRI with other modality(CT, single photon emission computed tomography, echocardiography). First, mean difference for the measurement of EF(%) is CT ±2.7, SPECT ±6.7, echocardiography: ±7.01. Second, end-diastolic volume(EDV) value(ml), mean of difference is CT: ±18.3, SPECT ±44.1 except echocardiography(because echocardiography is not volume but two dimentional diameter). Third, end-systolic volume(ESV) value(ml), mean of difference is CT: ±8.57, SPECT ±15.9 also except echocardiography. At last, left ventricle mass score is only compare MRI with CT and not include papillary muscle. Mean of difference is CT: ±8.09.
Conclusion
From thisstudy, we concluded that ECG-gated MDCT is more accurate than SPECT or echocardiography for the assessment of cardiac function. According to MDCT is rapidly developed like as 64 MDCT, improvement of temporal resolution bring to reduce artifact that is influenced heart rate. Therefore MDCT will play an important role in the near future for the evaluation of cardiac functional analysis.
목차
Ⅰ. 목적
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
