- 영문명
- A Study for Optimal Enhancement According to Change of the Locator in Brain Computed Tomographic Angiography
- 발행기관
- 대한CT영상기술학회
- 저자명
- 전필현(Pil Hyun Jeon) 이원형(Won Hyung Lee) 전성수(Seang Su Jeon)
- 간행물 정보
- 『대한CT영상기술학회지』대한전산화단층기술학회지 제12권 제2호, 21~26쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2010.09.30

국문 초록
영문 초록
Purpose
In contrast enhanced imaging, a contrast agent is introduced into the anatomy of a patient, typically by way of an intravenous or intra-arterial injection. Following a delay which allows the contrast agent to reach a region of interest(ROI) of the patient’s anatomy, a scan of the region is initiated. A bolus tracking scan is coordinated to coincide with the presence of the contrast agent at the ROI, as scanning either too early or too late can result in less dian optimal enhancement, and possibly require that the patient be rescanned. To achieve standard contrast enhancement appropriately throughout the location of the target vessels, this study was undertaken the locator placed in the descending aorta for the brain computed tomographic angiography(CTA).
Materials and methods
The study was conducted using brain CTA for patients who presented at our hospital from November 2009 to February 2010. Optimization of bolus timing was used at a place of the locator in the descending aorta via a 64-detector row CT brain angiography.
Results
When compared place descending aorta in the locator with internal carotid artery and random locator around avoiding the neck vessels, descending aorta in the locator more contrast enhancement. So the cases reduce probability protect missing the enhancement time and the target regions and increasing three-dimensional processing time.
Conclusion
This study is reduced that more insufficient arterial contrast or excessive venous enhancement, which can be placed of a locator in the descending artery. And that is good arterial contrast with little venous contamination. Our investigation provides to the optimal enhance time product by merging the three-dimensional representations of circle of willis portion and common carotid artery bifurcation more than valuable diagnostic images for helpful diagnosis and therapy using optimal enhancement according to change of locator in brain CTA.
목차
Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
해당간행물 수록 논문
참고문헌
최근 이용한 논문