Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma
reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot
multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter (UV254) in sewage.
Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge
electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and
a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we
performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge
voltage.
Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in
batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge
voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In
continuous operation of the air plasma process, residual microorganisms, UV254 absorbance and TOC removal
rate at optimal condition of 13 kV were 102.24 CFU/mL, 56.5% and 8.6%, respectively, while in oxygen
plasma process at 10 kV, residual microorganisms, UV254 absorbance and TOC removal rate at optimal
conditions were 101.0 CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially
with the increase in high voltage (R2 = 0.9964).
Electric power = 0.0492×exp(0.6027×electric discharge voltage)
Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The
performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen
plasma process was less than that of air plasma process. However, it was considered that the final evaluation of
air and oxygen plasma must be evaluated by considering low power consumption, high process performance,
operating costs and facility expenses of an oxygen generator.