- 영문명
- A PHOTOELASTIC STUDY ON EFFECTS OF BONE REDUCTION FORCEPS ON MANDIBULAR FRACTURE REDUCTION
- 발행기관
- 대한구강악안면외과학회
- 저자명
- 박진형(Jin-Hyoung Park) 최병호(Byung-Ho Choi) 류태민(Tae-Min Yoo) 허진영(Jin-Young Huh)
- 간행물 정보
- 『대한구강악안면외과학회지』대한구강악안면외과학회지 제28권 제6호, 464~471쪽, 전체 8쪽
- 주제분류
- 의약학 > 내과학
- 파일형태
- 발행일자
- 2002.12.30
국문 초록
영문 초록
The purpose of this study was to evaluate the stress patterns within fractured mandibles generated by reduction forceps and to determine the optimal position of the reduction forcep. Twenty-seven mandibular models were fabricated using a photoelastic resin. Each of the three sets of mandible models prepared was osteotomized according to one of three different fracture types(symphysis, parasymphysis and body fractures).
After reducing the cut segments, a reduction forcep was placed into different engagement holes to compress
the segments. Photoelastic stress analysis was used to visualize the stress patterns within the fractured
mandiblular models generated by the reduction forcep.
In the case of symphysis or parasymphysis fractures, an optimum distribution of stress over the fracture site was achieved when placing the reduction forcep more than 12.5㎜ on either side of the fracture line between the midway level bisecting the mandible and 5㎜ below the level. In the case of body fractures, optimum stress distribution was achieved when the reduction forcep was placed more than 15㎜ from the fracture line on the midway level. In conclusion, a correct use of reduction forceps helps to provide a precise threedimensional reduction for mandibular fractures.
목차
키워드
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!