본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

각막 구면수차의 교정을 동반한 백내장 수술의 임상 결과 분석

이용수 3

영문명
Clinical Outcomes of Cataract Surgery with Correction of Corneal Spherical Aberration
발행기관
대한안과학회
저자명
이진호 최혁진 김미금 위원량,Jinho Lee, MD, Hyuk Jin Choi, MD, Mee Kum Kim, MD, PhD, Won Ryang Wee, MD, PhD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume55,number6, 809~816쪽, 전체 8쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2014.06.15
이용가능 이용불가
  • sam무제한 이용권 으로 학술논문 이용이 가능합니다.
  • 이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다. 1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To evaluate preoperative and postoperative spherical aberrations after cataract surgery based on selecting spherical or aspheric intraocular lens (IOL) according to preoperative corneal aberration. Methods: The medical records of patients who underwent phacoemulsification and IOL implantation in the posterior chamber by a surgeon (H.J.C) were reviewed (68 patients, 97 eyes). IOL was selected based on preoperative corneal spherical aberration measured by corneal topography (ATLAS 9000, Carl Zeiss). The target postoperative total ocular spherical aberration was set to zero (0) and one of the following lenses was chosen: Acrysof SA60AT (n = 25), Acrysof IQ (n = 36) or Tecnis® ZCB00 (n = 36). The Wavescan aberrometer and the corneal topography were obtained postoperatively. Absolute prediction errors of postoperative total ocular spherical aberration were analyzed. Results: Preoperative corneal spherical aberration was 0.241 μm; total postoperative ocular spherical aberration was 0.0509 μm (Acrysof SA60AT: 0.0954 μm, Tecnis® ZCB00: 0.0374 μm, Acrysof IQ: 0.0335 μm). Postoperative corneal spherical aberration was 0.232 μm, which was not significantly different from the preoperative value (p = 0.199). Postoperative ocular spherical aberration was 0.051 μm; 0.095 μm (Acrysof SA60AT), 0.034 μm (Acrysof IQ), and 0.037 μm (ZCB00). The reducing amounts of spherical aberration were 0.185 μm (Acrysof IQ) and 0.311 μm (ZCB00). The overall absolute prediction error was 0.068 μm. The absolute prediction error of the Acrysof SA60AT group was 0.092 μm, Tecnis® ZCB00 group was 0.067 μm and Acrysof IQ group was 0.054 μm. There was no significant difference among the 3 groups (p = 0.089). Conclusions: Aspheric IOLs can efficiently reduce total ocular spherical aberrations according to preoperative corneal spherical aberrations. J Korean Ophthalmol Soc 2014;55(6):809-816

목차

키워드

해당간행물 수록 논문

참고문헌

최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이진호,최혁진,김미금,위원량,Jinho Lee, MD, Hyuk Jin Choi, MD, Mee Kum Kim, MD, PhD, Won Ryang Wee, MD, PhD. (2014).각막 구면수차의 교정을 동반한 백내장 수술의 임상 결과 분석. 대한안과학회지, 55 (6), 809-816

MLA

이진호,최혁진,김미금,위원량,Jinho Lee, MD, Hyuk Jin Choi, MD, Mee Kum Kim, MD, PhD, Won Ryang Wee, MD, PhD. "각막 구면수차의 교정을 동반한 백내장 수술의 임상 결과 분석." 대한안과학회지, 55.6(2014): 809-816

sam 이용권 선택
님이 보유하신 이용권입니다.
차감하실 sam이용권을 선택하세요.