- Analysis of Miscorrection after Implantation of the Toric Intraocular Lens
- 발행기관
- 대한안과학회
- 저자명
- 전혜민 이경헌,Hye Min Jeon, MD, Kyung Heon Lee, MD
- 간행물 정보
- 『대한안과학회지』Ophthalmological Society,volume55,number11, 1636~1641쪽, 전체 6쪽
- 주제분류
- 인문학 > 역사학
- 파일형태
- 발행일자
- 2014.11.15

국문 초록
영문 초록
Purpose: To evaluate the efficacy and stability of AcrySof Toric intraocular lens (IOL) implants and to analyze the miscorrection that resulted after implantation. Methods: This retrospective study included 422 eyes of 348 patients who underwent cataract surgery with implantation of the AcrySof toric IOL between December 2011 and June 2013. We evaluated uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), keratometry and refraction preoperatively and 3 months postoperatively. The axis of implanted AcrySof Toric IOL was measured using the KR-1W aberrometer before mydriasis. At 3 months postoperatively, patients with a residual cylindrical power of 0.50 diopters (D) or more, and having an IOL rotation of 10 degrees (°) or more were considered having miscorrection. Results: UCVA (log MAR) improved from 0.58 ± 0.35 to 0.18 ± 0.26. Preoperative corneal astigmatism was 1.46 ± 0.72 D and postoperative refractive cylindrical power was 0.45 ± 0.30 D. The postoperative miscorrection was 50.5% in the T3 group, 35.7% in the T4 group, and 27.2% in the T5 group. The incidence of overcorrection was significantly higher in the T3 group than in the T4 and T5 group. In eyes with with-the-rule (WTR) astigmatism, overcorrection was found in 36.4% (32/88 eyes), while in eyes with against-the-rule (ATR) astigmatism, undercorrection was found in 37.6% of cases (44/117 eyes). There were five cases of IOL rotation at 3 months postoperatively. Conclusions: AcrySof Toric IOL was effective in correcting corneal astigmatism and had good rotational stability. However, the incidence of miscorrection, especially for overcorrection, was higher with lower power toric IOL. Patients with WTR astigmatism tend to have overcorrection, while those with ATR show a tendency toward undercorrection, suggesting that these changes considered at the time of cataract surgery.J Korean Ophthalmol Soc 2014;55(11):1636-1641
목차
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!