- 영문명
- Diagnostic Criteria of Pattern VEP in Adult Monocular Amblyopic Patients
- 발행기관
- 대한안과학회
- 저자명
- 임선희 임기환,Sun Hee Lim, MD, Key Hwan Lim, MD, PhD
- 간행물 정보
- 『대한안과학회지』Ophthalmological Society,volume54,number12, 1875~1881쪽, 전체 7쪽
- 주제분류
- 인문학 > 역사학
- 파일형태
- 발행일자
- 2013.12.13

국문 초록
영문 초록
Purpose: To suggest a diagnostic criteria of pattern visual evoked potential (VEP) in adult monocular amblyopic patients in comparison to normal subjects.
Methods: The medical records of patients’ military service certificates from January 2000 to December 2011 were reviewed. The parameters of pattern VEP were analyzed by comparing monocular amblyopic patients with normal controls.
Results: This study included 47 monocular amblyopia and 39 normal control patients. All parameters of pattern VEP were statistically significantly different between monocular amblyopic eyes and normal eyes. The cut-off values for diagnosis of adult amblyopia using receiver operating characteristic (ROC) curve were 113.50 msec (P100 latency), 1.05 (ratio of P100 latency), 8.50 msec (interocular difference of P100 latency), and 5.25 μV (interocular difference of P100 amplitude). Cut-off value sensitivities were generally low: (51.1%, 70.2%, 53.2%, and 31.9%, respectively).
Conclusions: The value of pattern VEP parameters had limitations due to low sensitivity and could be considered as ancillary diagnostic criteria when diagnosing amblyopia.
J Korean Ophthalmol Soc 2013;54(12):1875-1881
Methods: The medical records of patients’ military service certificates from January 2000 to December 2011 were reviewed. The parameters of pattern VEP were analyzed by comparing monocular amblyopic patients with normal controls.
Results: This study included 47 monocular amblyopia and 39 normal control patients. All parameters of pattern VEP were statistically significantly different between monocular amblyopic eyes and normal eyes. The cut-off values for diagnosis of adult amblyopia using receiver operating characteristic (ROC) curve were 113.50 msec (P100 latency), 1.05 (ratio of P100 latency), 8.50 msec (interocular difference of P100 latency), and 5.25 μV (interocular difference of P100 amplitude). Cut-off value sensitivities were generally low: (51.1%, 70.2%, 53.2%, and 31.9%, respectively).
Conclusions: The value of pattern VEP parameters had limitations due to low sensitivity and could be considered as ancillary diagnostic criteria when diagnosing amblyopia.
J Korean Ophthalmol Soc 2013;54(12):1875-1881
목차
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
