Purpose: To compare the size, circularity and repeatability between the conventional manual technique and the open-ring guided continuous curvilinear capsulorrhexis (CCC) technique in cataract surgery. Methods: The present study comprised 120 eyes divided into two equal groups. In the first group (group A), CCC was performed using a 5.3-mm open ring-shaped caliper and in the second group (group B), CCC was performed using the conventional manual technique. Photographs were taken after each surgical step (CCC, phacoemulsification, Intraocular lens insertion and corneal stromal hydration). The diameter, area and circularity of the anterior capsule were compared between the two groups. Results: The anterior capsule diameter was 5.32 ± 0.26 mm for group A (coefficient of variation 0.049) and 5.14 ± 0.64 mm for group B (coefficient of variation 0.125); the area was 22.9 ± 0.71 mm2 for group A (coefficient of variation 0.031) and 21.40 ± 1.37 mm2 for group B (coefficient of variation 0.064). Circularity was 0.93 ± 0.24 for group A (coefficient of variation 0.258) and 0.86 ± 0.78 for group B (coefficient of variation 0.907). Conclusions: The open ring-guided CCC technique resulted in an increase of diameter and capsulorrhexis area. This method showed superior circularity and repeatability compared to conventional manual technique and can be useful in cataract surgery.
목차
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!