- 영문명
- Comparison of Frequency Doubling Technology Perimeter and RNFL Photography for Early Diagnosis of Glaucoma
- 발행기관
- 대한안과학회
- 저자명
- 이준성 허환 박상우 양건진,Jun Sung Lee, MD, Hwan Heo, MD, Sang Woo Park, MD, Kun-Jin Yang, MD
- 간행물 정보
- 『대한안과학회지』Ophthalmological Society,volume50,number11, 1674~1679쪽, 전체 6쪽
- 주제분류
- 의약학 > 의학일반
- 파일형태
- 발행일자
- 2009.11.15
국문 초록
영문 초록
Purpose: To compare the frequency doubling technology perimeter (FDT) with retinal nerve fiber layer (RNFL) photography as a tool for the early detection of glaucoma. Methods: Ninety-eight eyes of 98 patients were evaluated over a period of 3 months. According to the results of RNFL photography and FDT, Patients were divided into four groups based on the results of RNFL photography and optical coherence tomography (OCT). A comparison of the RNFL thickness of each group was performed using the OCT results. Results: RNFL thickness in the group with abnormal FDT and normal RNFL were significantly decreased from those in the group with normal FDT and RNFL photography at the 6, 7 and, 10 o’clock area (p<0.05). Conclusions: There were statistically significant differences in the RNFL thickness between the group with abnormal FDT and normal RNFL photography, and the group with normal FDT and RNFL photography within the limited areas. These results imply that FDT is more useful for the early detection of glaucoma than RNFL photography. J Korean Ophthalmol Soc 2009;50(11):1674-1679