- 영문명
- Perfluoro-N-octane as Postoperative Vitreous Substitutes in Retinal Detachment: A Case Report
- 발행기관
- 대한안과학회
- 저자명
- 장영석 길현경 김철구,Young Suk Chang, M.D., Hyun Kyung Ghil, M.D., Chul Gu Kim, M.D.
- 간행물 정보
- 『대한안과학회지』Ophthalmological Society,volume49,number3, 525~530쪽, 전체 6쪽
- 주제분류
- 의약학 > 기타의약학
- 파일형태
- 발행일자
- 2008.03.31

국문 초록
영문 초록
`Purpose: To report a case of retinal detachment with a giant retinal tear, which was treated with perfluorocarbon liquid as an intraocular substitute. Case summary: A 37-year-old woman with a dislocated lens and a giant retinal tear underwent vitrectomy and lensectomy and was instructed to maintain a supine position after the operation. Perfluorocarbon liquid (Perfluoro-N-octane, C8F18) was used as a substitute in the vitreous cavity for 17 days. After 17 days, the perfluorocarbon liquid was removed and intraocular lens scleral fixation was performed. After removal of the perfluorocarbon liquid, the corneal endothelium was stable without other complications (including corneal edema, elevated intraocular pressure, ocular hypotony, macular pucker), and the best corrected visual acuity after intraocular lens scleral fixation was 0.4. Conclusions: Perfluorocarbon liquid is a useful surgical material in patients with a dislocated lens and retinal detachment with a giant retinal tear who have difficulty maintaining a prone position.`