- 영문명
- Assessment of the Anterior Segment Using Slit-Lamp Biomicroscope and Gonioscope
- 발행기관
- 대한안과학회
- 저자명
- 오종현 김용연 정해륜,Jong Hyun Oh, M.D., Yong Yeon Kim, M.D., Hai Ryun Jung, M.D.
- 간행물 정보
- 『대한안과학회지』Ophthalmological Society,volume47,number9, 1435~1443쪽, 전체 9쪽
- 주제분류
- 의약학 > 기타의약학
- 파일형태
- 발행일자
- 2006.09.30

국문 초록
영문 초록
Purpose: To evaluate the accuracy of the Smith method, van Herick technique, and Shaffer grading system, using a slit-lamp biomicroscope and gonioscope that measure anterior chamber depth (ACD), peripheral chamber depth (PCD), and angle width. Methods: The anterior chamber of 94 eyes of 53 subjects was evaluated by slit-lamp examination with a gonioscope. An A-scan was carried out on all of the subjects, but ultrasound biomicroscope (UBM) was performed on only 42 of 94 eyes. Slit-lamp biomicroscope-assisted measurements, such as ACD, PCD, and angle width, were compared with those by A-scan and UBM. Results: The correlations among ACD measurements, obtained by the Smith method, and those obtained using A-scan (r=0.673, p<0.001) and UBM (r=0.824, p<0.001) were statistically significant. The mean PCD, measured by van Herick technique, was 14.01±15.04 %, and its correlation with that of UBM was statistically significant (r=0.706, p<0.001). In addition, the correlation between the mean angle width, measured by Shaffer grading system and by UBM, was also statistically significant (r=0.853, p<0.001). Conclusions: Assessments of the anterior segment, using a slit-lamp biomicrosope and a gonioscope, are comparable to those of A-scan and UBM measurements and are, therefore, useful for evaluation of the anterior chamber.
목차
해당간행물 수록 논문
참고문헌
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
