본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Comparison of Femoral Anteversion Angle and Determination of Reliability Measured at Three Different Anatomical References of the Tibial Crest During the Trochanteric Prominence Angle Test

이용수 0

영문명
발행기관
한국전문물리치료학회
저자명
Ji-hyun Lee Tae-lim Yoon Sil-ah Choi Heon-seock Cynn
간행물 정보
『한국전문물리치료학회지』한국전문물리치료학회지 제19권 제4호, 55~60쪽, 전체 6쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
2012.10.31
이용가능 이용불가
  • sam무제한 이용권 으로 학술논문 이용이 가능합니다.
  • 이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다. 1:1 문의
논문 표지

국문 초록

영문 초록

The trochanteric prominence angle test (TPAT) has been used to measure the femoral anteversion angle between the tibial crest and the vertical line. However, the exact anatomical reference of the tibial crest has not yet been identified in the literature. Thus, the purposes of this research were twofold: first, to compare the femoral anteversion angle measured at three different anatomical references of the tibial crest (the proximal tibial crest, the proximal third of tibial crest, and the proximal half of tibial crest) and, second, to determine inter-and intra-rater reliabilities of the femoral anteversion angle measured at these three different anatomical references of the tibial crest during the TPAT. We recruited 14 healthy subjects, and a total of 28 legs were examined. The TPAT was measured using a digital inclinometer. A 1-way repeated-measure analysis of variance was used to compare the femoral anteversion angle measured at three different anatomical references of the tibial crest, and intraclass correlation coefficients (ICCs) were calculated to determine reliability. The femoral anteversion angle measured at the proximal tibial crest was significantly higher than that at the proximal third of the tibial crest and the proximal half of the tibial crest. The inter-and intra-rater reliabilities of femoral anteversion angle were measured at three anatomic references of the tibial crest were all found to be high during the TPAT (ICC=.9 0~.98). In conclusion, clinicians should recognize that the different degrees of the femoral anteversion angle could be measured when different anatomical references of the tibial crest were used, and that reliabilities were high when an exact anatomical reference of the tibial crest was used during the TPAT.

목차

Abstract
Introduction
Methods
Results
Discussion
Conclusion
References

키워드

해당간행물 수록 논문

참고문헌

최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Ji-hyun Lee,Tae-lim Yoon,Sil-ah Choi,Heon-seock Cynn. (2012).Comparison of Femoral Anteversion Angle and Determination of Reliability Measured at Three Different Anatomical References of the Tibial Crest During the Trochanteric Prominence Angle Test. 한국전문물리치료학회지, 19 (4), 55-60

MLA

Ji-hyun Lee,Tae-lim Yoon,Sil-ah Choi,Heon-seock Cynn. "Comparison of Femoral Anteversion Angle and Determination of Reliability Measured at Three Different Anatomical References of the Tibial Crest During the Trochanteric Prominence Angle Test." 한국전문물리치료학회지, 19.4(2012): 55-60

sam 이용권 선택
님이 보유하신 이용권입니다.
차감하실 sam이용권을 선택하세요.