본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation

이용수  0

영문명
발행기관
대한치과교정학회
저자명
Dong-Woo Kim Hyun-Jun Lee Ki Beom Kim Sung-Hun Kim Seong-Sik Kim Soo-Byung Park Youn-Kyung Choi Yong-Il Kim
간행물 정보
『The Korean Journal of Orthodontics』제55권 제3호, 212~223쪽, 전체 12쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2025.05.25
무료

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

Objective: To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC- 85 clear aligners (CAs), with various margin designs, during premolar rotation. Methods: In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins. Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes. Results: The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles. Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners. Conclusions: Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

영문 초록

목차

INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
CONCLUSIONS

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

Dong-Woo Kim,Hyun-Jun Lee,Ki Beom Kim,Sung-Hun Kim,Seong-Sik Kim,Soo-Byung Park,Youn-Kyung Choi,Yong-Il Kim. (2025).Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation. The Korean Journal of Orthodontics, 55 (3), 212-223

MLA

Dong-Woo Kim,Hyun-Jun Lee,Ki Beom Kim,Sung-Hun Kim,Seong-Sik Kim,Soo-Byung Park,Youn-Kyung Choi,Yong-Il Kim. "Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation." The Korean Journal of Orthodontics, 55.3(2025): 212-223

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제